MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10840-019-00647-3

Медицинская библиотека · Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2019

Nanostim leadless pacemaker retrieval and simultaneous micra leadless pacemaker replacement: a single-center experience.

Asirvatham Roshini S, Vaidya Vaibhav R, Thome Trena M, Friedman Paul A, Cha Yong-Mei

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The leadless pacemaker (LP) is a promising new technology in pacing therapy that avoids a generator pocket and transvenous lead-related complications. However, extraction experience with simultaneous re-implant of a leadless device remains limited. We sought to study the outcomes of Nanostim LP retrieval and simultaneous reimplantation of Micra LP.

METHODS

Patients undergoing retrieval of the Nanostim LP and receiving a Micra LP implant between 2016 and 2018 at Mayo Clinic (Rochester, MN) were studied. The procedural and outcome data were collected from the electronic medical record.

RESULTS

Nine patients underwent attempted Nanostim LP retrieval and 6 of these simultaneously received a Micra LP reimplant. All retrievals were considered chronic due to implant durations of > 1 year. Extraction procedures were completed with a success rate of 89% and simultaneous reimplantations were performed successfully in all cases with no major complications. Newly implanted Micra LP device function was normal at follow-up. Factors such as duration of device implant and device positioning appeared to impact ease of extraction.

CONCLUSIONS

Retrieval of the Nanostim LP system and simultaneous replacement with an alternate Micra leadless device appears to be a feasible approach.

Для цитирования: Asirvatham Roshini S, Vaidya Vaibhav R, Thome Trena M, Friedman Paul A, Cha Yong-Mei. Nanostim leadless pacemaker retrieval and simultaneous micra leadless pacemaker replacement: a single-center experience.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2019. DOI: 10.1007/s10840-019-00647-3.