Catheter-induced premature ventricular complexes (PVCs) may aid in the determination of optimal timing for clinical PVC ablation.

Demir Serdar, Akgun Taylan, Gulsen Kamil, Kup Ayhan, Uslu Abdulkadir, Kayan Fethullah, Kepez Alper

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The aim of the present study is to evaluate whether catheter-induced premature ventricular complexes (PVCs) produced at the presumptive ablation site may aid in the identification of the optimal timing of the earliest local activation for the successful ablation of clinical PVCs.

METHODS

Sixty-three consecutive patients (35 males, age: 53.5 ± 14.4 years) without any exclusion criteria who had undergone PVC ablation between 1 July 2018 and 1 July 2019 constituted our study population. The time interval between the beginning of the EGM and the beginning of the QRS of each catheter-induced PVC (Cath EGM-ECG) and the time interval between the beginning of the EGM of clinical PVCs at the earliest site and the beginning of the QRS of clinical PVCs (PVC earliest EGM-ECG) were noted for each patient. The value of Cath EGM-ECG as a reference for procedural success of ablation was evaluated by examining the relationship between Cath EGM-ECG and PVC earliest EGM-ECG.

RESULTS

Fifty-two patients had successful ablation, and 43 of them (82.7%) had PVC earliest EGM-ECG values greater than or equal to Cath EGM-ECG. Eleven patients had procedural failure, and all of them had PVC earliest EGM-ECG values lower than Cath EGM-ECG. A PVC earliest EGM-ECG value -1.5 ms greater than Cath EGM-ECG predicted successful ablation with a sensitivity of 90.4% and a specificity of 100.0% in the general patient population.

CONCLUSION

Cath EGM-ECG seems to serve as a reliable guide for finding the optimal timing of the earliest site for successful PVC ablation.

Для цитирования: Demir Serdar, Akgun Taylan, Gulsen Kamil, Kup Ayhan, Uslu Abdulkadir, Kayan Fethullah, Kepez Alper. Catheter-induced premature ventricular complexes (PVCs) may aid in the determination of optimal timing for clinical PVC ablation.. Pacing and clinical electrophysiology : PACE. 2019. DOI: 10.1111/pace.13833.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.