MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.28530

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2019

Long-term clinical outcomes of Amplatzer cardiac plug versus Amulet occluders for left atrial appendage closure.

Kleinecke Caroline, Cheikh-Ibrahim Mohammad, Schnupp Steffen, Fankhauser Mate, Nietlispach Fabian, Park Jai-Wun, Brachmann Johannes, Windecker Stephan, Meier Bernhard, Gloekler Steffen

Сравнительное исследованиеСтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

To compare long-term clinical outcomes after left atrial appendage closure with the Amplatzer Cardiac Plug (ACP) and Amulet.

BACKGROUND

The Amulet was designed to improve clinical outcomes of first-generation ACP.

METHODS

Three Amplatzer registries (Bern, Coburg, Zurich), with enrollment of patients from 2009 to 2018, were retrospectively analyzed. The primary safety endpoint was a composite of major peri-procedural complications and major bleedings, the primary efficacy endpoint included stroke, systemic embolism, and cardiovascular/unexplained death. The net clinical benefit was a combination of all above-mentioned hazards.

RESULTS

A total of consecutive 563 patients (344 ACP vs. 219 Amulet) with a mean follow-up of 2.9 ± 1.6 and 1.9 ± 0.9 years were included. Mean age (74.4 ± 9.9 [ACP] vs. 74.4 ± 9.1 [Amulet] years), stroke (CHA2 DS2 -VASc score 4.4 ± 1.6 vs. 4.6 ± 1.7), and bleeding risk (HAS-BLED score 3.2 ± 1.1 vs. 3.2 ± 0.9) were comparable. The primary endpoints of efficacy (72/998, 7.2% [ACP] vs. 43/417, 10.3% [Amulet]; hazard ratio [HR], 0.67; 95% confidence interval [CI], 0.44-1.02, p = .062), safety (40/998, 4.0% vs. 18/417, 4.3%; HR, 1.15; 95% CI, 0.53-2.51, p = .72), and the net clinical benefit (101/998, 10.1% vs. 55/417, 13.4%; HR, 0.73; 95% CI, 0.49-1.07, p = .11) were similar.

CONCLUSION

In the long term, left atrial appendage closure with first and second-generation Amplatzer devices provided similar efficacy, safety, and net clinical benefit. Clinical outcomes may be rather determined by implantation technique and hemodynamics, but not by the design modifications of the Amulet.

Для цитирования: Kleinecke Caroline, Cheikh-Ibrahim Mohammad, Schnupp Steffen, Fankhauser Mate, Nietlispach Fabian, Park Jai-Wun, Brachmann Johannes, Windecker Stephan, Meier Bernhard, Gloekler Steffen. Long-term clinical outcomes of Amplatzer cardiac plug versus Amulet occluders for left atrial appendage closure.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2019. DOI: 10.1002/ccd.28530.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.