DOI 10.1016/j.ejmp.2022.07.003
Assessment of a computed tomography-based radiomics approach for assessing lung function in lung cancer patients.
Аннотация
PURPOSE: We aimed to assess radiomics approaches for estimating three pulmonary function test (PFT) results (forced expiratory volume in one second [FEV1], forced vital capacity [FVC], and the ratio of FEV1 to FVC [FEV1/FVC]) using data extracted from chest computed tomography (CT) images.
METHODS
This retrospective study included 85 lung cancer patients (mean age, 75 years ±8; 69 men) who underwent stereotactic body radiotherapy between 2012 and 2020. Their pretreatment chest breath-hold CT and PFT data before radiotherapy were obtained. A total of 107 radiomics features (Shape: 14, Intensity: 18, Texture: 75) were extracted using two methods: extraction of the lung tissue (<-250 HU) (APPROACH 1), and extraction of small blood vessels and lung tissue (APPROACH 2). The PFT results were estimated using the least absolute shrinkage and selection operator regression. Pearson's correlation coefficients (r) were determined for all PFT results, and the area under the curve (AUC) was calculated for FEV1/FVC (<70 %). Finally, we compared our approaches with the conventional formula (Conventional).
RESULTS
For the estimated FEV1/FVC, the Pearson's r were 0.21 (P =.06), 0.69 (P <.01), and 0.73 (P <.01) for Conventional, APPROACH 1, and APPROACH 2, respectively; the AUCs for FEV1/FVC (<70 %) were 0.67 (95 % confidence interval [CI]: 0.55, 0.79), 0.82 (CI: 0.72, 0.91; P =.047) and 0.86 (CI: 0.78, 0.94; P =.01), respectively.
CONCLUSIONS
The radiomics approach performed better than the conventional equation and may be useful for assessing lung function based on CT images.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.