BACKGROUND

Inulin/sinistrin (I/S) clearance is a gold standard for an accurate assessment of glomerular filtration rate (GFR). Here we describe and validate an approach for a transcutaneous determination of GFR by using fluorescein-isothiocyanate-labelled sinistrin (FITC-S) in rats.

METHODS

Using a small animal imager, fluorescence is measured over the depilated ear of a rat after the injection of FITC-S. The decay curve of fluorescence is used for the calculation of half-life and GFR. The thus obtained transcutaneous data were validated by simultaneously performed enzymatic and fluorometric measurements in plasma of both FITC-S and sinistrin.

RESULTS

The results of enzymatic sinistrin determination versus transcutaneous half-life of FITC-S or plasma fluorescence correlated well with each other (R(2) > 0.90). Furthermore, Bland-Altman analyses proved a good degree of agreement of the three methods used. The measurements performed in healthy animals as well as different models of renal failure demonstrate its appropriateness in a wide range of renal function.

CONCLUSIONS

The transcutaneous method described offers a precise assessment of GFR in small animals. As neither blood and/or urine sampling nor time-consuming lab work is required, GFR can be determined immediately after the clearance procedure is finished. This method, therefore, simplifies and fastens GFR determinations in small lab animals compared to conventional bolus clearance techniques based on blood sampling. A low-cost device for the measurement of transcutaneous fluorescence intensity over time is under construction.

Для цитирования: Schock-Kusch Daniel, Sadick Maliha, Henninger Nadja, Kraenzlin Bettina, Claus Guenter, Kloetzer Hans-Martin, Weiss Christel, Pill Johannes, Gretz Norbert. Transcutaneous measurement of glomerular filtration rate using FITC-sinistrin in rats.. Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association. 2009. DOI: 10.1093/ndt/gfp225.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.