MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jchromb.2009.04.017

Медицинская библиотека · Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2009

Detection of landiolol using high-performance liquid chromatography/fluorescence: a blood esterase-sensitive ultra-short-acting beta(1)-receptor antagonist.

Suno Manabu, Kunisawa Takayuki, Yamagishi Akio, Ono Takashi, Yamamoto Joe, Yamada Takehiro, Tasaki Yoshikazu, Shimizu Keiko, Iwasaki Hiroshi, Matsubara Kazuo

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

Landiolol hydrochloride, a new adrenergic beta(1)-selective antagonist having an ultra-short half-life, is used to prevent tachyarrhythmia during surgery. Since landiolol is thought to be rapidly hydrolyzed to an inactivate metabolite by esterases, quantification of the drug concentration in the blood is impractical. The landiolol concentration in blood was halved within 5 min after blood sampling. This degradation was effectively prevented by pre-treatment with neostigmine (100 microg) in the sampling tube, but not by EDTA pre-treatment, indicating that landiolol could be metabolized by pseudocholinesterase in plasma. After the one-step solid-phase extraction, fluorescence detection of landiolol reduced chromatographic background signals and then improved assay sensitivity to the lower limit of 10 ng/ml in blood; this reproducible approach yielded coefficient variation of less than 6%. The blood concentration-time profile of landiolol hydrochloride in patients of the present investigation afforded more practical assessment than previously reported studies, thus improving accuracy and facilitating detailed pharmacokinetic study in relation to the pharmacological action of drug.

Для цитирования: Suno Manabu, Kunisawa Takayuki, Yamagishi Akio, Ono Takashi, Yamamoto Joe, Yamada Takehiro, Tasaki Yoshikazu, Shimizu Keiko, Iwasaki Hiroshi, Matsubara Kazuo. Detection of landiolol using high-performance liquid chromatography/fluorescence: a blood esterase-sensitive ultra-short-acting beta(1)-receptor antagonist.. Journal of chromatography. B, Analytical technologies in the biomedical and life sciences. 2009. DOI: 10.1016/j.jchromb.2009.04.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.