DOI 10.1016/j.jmoldx.2018.08.012

Медицинская библиотека · The Journal of molecular diagnostics : JMD · 2018

Optimized Digital Droplet PCR for BCR-ABL.

Maier Jacqueline, Lange Thoralf, Cross Michael, Wildenberger Kathrin, Niederwieser Dietger, Franke Georg-Nikolaus

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Quantitative real-time PCR methods are commonly used to monitor BCR-ABL transcript levels in patients with chronic myelogenous leukemia. However, standard techniques involve separate measurements of target and reference DNAs, require standard curves, and are susceptible to PCR inhibition. An optimized duplex droplet digital PCR (ddPCR) should provide absolute quantification without the need for standard curves. The combination of high sensitivity and low background is particularly important for reliable monitoring of minimal residual disease. In this report, we describe primer probe set testing and step by step optimization of a duplex ddPCR for BCR-ABL/ABL. The optimization of ddPCR parameters increased ABL and BCR-ABL fluorescence signals by two- and fivefold, respectively, and enhanced the resolution between positive and negative drops. The optimized procedure generates a background false-positive rate of 5% of samples and reliably detects BCR-ABL/ABL down to 1/100,000 (CV <10%), with a single BCR-ABL copy being detected in 54% of reactions performed in duplicate from a molecular remission (MR) 5 sample (limit of detection = 1). Assay of duplicates resulted in a detection rate of 100% and 92% for MR4 and MR4.5, respectively. Detection of MR4.5 was increased to 100% by analyzing quadruplicates. Selection of an optimal primer and probe combination and stepwise optimization of the ddPCR conditions has yielded a robust low-background duplex ddPCR procedure for BCR-ABL/ABL.

Для цитирования: Maier Jacqueline, Lange Thoralf, Cross Michael, Wildenberger Kathrin, Niederwieser Dietger, Franke Georg-Nikolaus. Optimized Digital Droplet PCR for BCR-ABL.. The Journal of molecular diagnostics : JMD. 2018. DOI: 10.1016/j.jmoldx.2018.08.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.