MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/bf02806331

Медицинская библиотека · Gastroenterologia Japonica · 1987

Clinical evaluation of autoantibodies to liver cell membrane specific antigen, liver specific lipoprotein, and Tamm-Horsfall glycoprotein in autoimmune chronic active hepatitis.

Morichika S, Arima T, Nagashima H

СтатьяПеревод пока не подготовлен

Аннотация

An enzyme-linked immunosorbent assay was developed to detect circulating autoantibodies to three liver cell membrane surface antigens, i.e., liver cell membrane specific antigen (LCM), liver specific lipoprotein (LSP), and Tamm-Horsfall glycoprotein (THGP). In autoimmune chronic active hepatitis (autoimmune CAH), the positive rate and mean titer (normal range, less than 5.5 units) for anti-LCM were 100% and 13.5 units before corticosteroid treatment and 100% and 9.9 units during the treatment. The corresponding values for anti-LSP were 84% and 11.8 units, and 81% and 8.9 units, and those for anti-THGP were 84% and 12.3 units, and 81% and 7.9 units. In an autoimmune CAH patient, elevation of the plasma levels of autoantibodies during the treatment apparently preceded the elevation of alanine aminotransferase (ALT). However, the ALT elevation induced by transcatheter arterial embolization was not associated with the elevation of these autoantibodies in an autoimmune CAH patient with hepatocellular carcinoma. In primary biliary cirrhosis, drug-induced hepatitis, and non-hepatic immunological disorders, the production of the three autoantibodies did not directly correlate with liver cell damage. These findings suggest that the elevation of autoantibodies against LCM, LSP, and THGP can be a useful guide for the prednisolone treatment of autoimmune CAH.

Для цитирования: Morichika S, Arima T, Nagashima H. Clinical evaluation of autoantibodies to liver cell membrane specific antigen, liver specific lipoprotein, and Tamm-Horsfall glycoprotein in autoimmune chronic active hepatitis.. Gastroenterologia Japonica. 1987. DOI: 10.1007/bf02806331.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.