MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · The International journal of oral & maxillofacial implants · 2009

Platform-switched restorations on wide-diameter implants: a 5-year clinical prospective study.

Vigolo Paolo, Givani Andrea

Сравнительное исследованиеКонтролируемое клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: The purpose of the present investigation was to clinically assess and compare crestal bone changes, over a 5-year period, around external-hexagon wide-diameter implants restored with either matching wide-diameter prosthetic components or with platform-switched prosthetic components.

MATERIALS AND

METHODS

During the years 2000 to 2002 all patients who received a single 5-mm-diameter implant with an external hexagon in a private office setting were included in this study. All implants were placed in the posterior areas of the jaws. Maxillary left molars (group A1) and mandibular right molars (group A2) were restored with matching wide-diameter prosthetic components; maxillary right molars (group B1) and mandibular left molars (group B2) were restored with platform-switched prosthetic components. Marginal bone resorption was measured via intraoral radiographs each year after abutment and crown insertion. Statistical analyses were used to determine whether there was a significant difference in marginal bone levels with respect to the width of prosthetic components used.

RESULTS

In all, 182 single 5-mm-diameter implants were placed in 144 patients and all implants survived. Eighty-five implants were restored with matching wide-diameter prosthetic components (group A), and 97 implants were restored with platform-switched prosthetic components (group B). A significant difference in marginal bone levels was found between group A and group B implants after 1 year. The mean marginal bone resorption was 0.9 mm (SD 0.3 mm) for group A implants and 0.6 mm (SD 0.2 mm) for group B implants. Marginal bone resorption observed at the second, third, fourth, and fifth years after abutment and crown insertion did not show any significant change.

CONCLUSION

Statistically significant differences in marginal bone loss were observed between study groups. The 85 implants restored with matching wide-diameter prosthetic components showed more bone loss than the 97 implants restored with platform-switched prosthetic components.

Для цитирования: Vigolo Paolo, Givani Andrea. Platform-switched restorations on wide-diameter implants: a 5-year clinical prospective study.. The International journal of oral & maxillofacial implants. 2009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.