MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajodo.2008.04.018

Медицинская библиотека · American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics · 2008

Alignment efficiency of Damon3 self-ligating and conventional orthodontic bracket systems: a randomized clinical trial.

Scott Paul, DiBiase Andrew T, Sherriff Martyn, Cobourne Martyn T

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

INTRODUCTION

The aim of this study was to compare the efficiency of mandibular tooth alignment and the clinical effectiveness of a self-ligating and a conventional preadjusted edgewise orthodontic bracket system.

METHODS

A multicenter randomized clinical trial was conducted in 2 orthodontic clinics. Sixty-two subjects (32 male, 30 female; mean age, 16.27 years) with mandibular incisor irregularities of 5 to 12 mm and a prescribed extraction pattern including the mandibular first premolars were randomly allocated to treatment with Damon3 self-ligating (Ormco, Glendora, Calif) or Synthesis (Ormco) conventionally ligated brackets. Fully ligated 0.014-in nickel-titanium archwires were used first in both groups, followed by a sequence of 0.014 x 0.025-in and 0.018 x 0.025-in nickel-titanium, and 0.019 x 0.025-in stainless steel. Study casts were taken at the start of treatment (T1), the first archwire change (T2), and the placement of the final 0.019 x 0.025-in archwire (T3). Cephalometric lateral skull and long-cone periapical radiographs of the mandibular incisors were taken at T1 and T3.

RESULTS

No significant difference was noted (P >0.05) in initial rate of alignment for either bracket system. Initial irregularity influenced subsequent rate of movement, but sex, age, and appliance type were statistically insignificant. Alignment was associated with an increase in intercanine width, a reduction in arch length, and proclination of the mandibular incisors for both appliances, but the differences were not significant. Incisor root resorption was not clinically significant and did not differ between systems.

CONCLUSIONS

Damon3 self-ligating brackets are no more efficient than conventional ligated preadjusted brackets during tooth alignment.

Для цитирования: Scott Paul, DiBiase Andrew T, Sherriff Martyn, Cobourne Martyn T. Alignment efficiency of Damon3 self-ligating and conventional orthodontic bracket systems: a randomized clinical trial.. American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics. 2008. DOI: 10.1016/j.ajodo.2008.04.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.