MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00270-026-04517-0

Медицинская библиотека · Cardiovascular and interventional radiology · 2026

Safety and Effectiveness in 400 Image-Guided Spleen Biopsies from the DeGIR Registry.

Ocker-Serger R, Opitz M, Klüner L, Drews M, Rosok D, Salhoefer L, Forsting M, Haubold J, Schaarschmidt B M, Zensen S

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

PURPOSE: To evaluate technical success, diagnostic yield, and complication rates of image-guided percutaneous splenic biopsies based on multicenter registry data from the German Society for Interventional Radiology and Minimally Invasive Therapy.

MATERIALS AND

METHODS

This retrospective multicenter study analyzed image-guided percutaneous splenic biopsies documented in the prospective DeGIR registry between 2018 and 2024. Technical success was defined as needle placement within the target lesion. Diagnostic yield was defined as histologically adequate samples enabling clinical diagnosis.

RESULTS

Four hundred splenic biopsies from 92 centers were included. Technical success was achieved in 99.00% of procedures. The complication rate was 5.00%, including 2.50% major complications with no procedure-related deaths. Complication rates were higher for procedures performed under local anesthesia than analgesic sedation (p = 0.042). Histopathological reports were available for 338 procedures, resulting in a diagnostic yield of 90.83%. Diagnostic yield increased with the number of biopsy samples, reaching a maximum with three samples. Procedures performed under analgesic sedation showed a higher diagnostic yield than those under local anesthesia (p = 0.019).

CONCLUSION

Image-guided percutaneous splenic biopsy is a safe and effective diagnostic procedure with high technical success and diagnostic yield. Analgesic sedation and obtaining up to three biopsy samples may improve diagnostic performance without increasing complication rates.

Для цитирования: Ocker-Serger R, Opitz M, Klüner L, Drews M, Rosok D, Salhoefer L, Forsting M, Haubold J, Schaarschmidt B M, Zensen S. Safety and Effectiveness in 400 Image-Guided Spleen Biopsies from the DeGIR Registry.. Cardiovascular and interventional radiology. 2026. DOI: 10.1007/s00270-026-04517-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.