MedElevator Войти в исследования
← Поиск публикаций

DOI 10.18502/jovr.v21.18164

Медицинская библиотека · Journal of ophthalmic & vision research · 2026

The Fundus Red Reflex Test Using a Smartphone Showed High Accuracy Compared to an Autorefractor to Detect Refractive Errors in Children.

Syauqie Muhammad, Rif'ati Lutfah, Diarsvitri Wienta, Hastono Sutanto Priyo, Siregar Kemal Nazaruddin, Moeloek Nila Djuwita Farieda

СтатьяПеревод в очереди

Аннотация

PURPOSE: To determine the accuracy of the fundus red reflex test using a smartphone and autorefractor to detect refractive errors in children.

METHODS

This cross-sectional study included 1302 eyes of 651 school-age children aged 6-13 years with visual acuity worse than 6/9 in at least one eye, examined using the Snellen chart. Study participants were selected using purposive sampling, after which non-cycloplegic refractive measurement was performed using two instruments: a smartphone-based application (MD EyeCare) and an autorefractor. The detection of refractive errors using the online platform was compared with autorefraction as the reference standard.

RESULTS

Our study found that 46.10% of participants with abnormal red reflex had significant myopia, 41.20% had nonsignificant refractive errors, and 12.70% had significant hypermetropia. The mean difference between the smartphone-based application and the autorefractor was ≤ - 3.00 D (range: - 2.88 to - 2.63), with a sensitivity of 0.89 to 0.90 and a specificity of 0.86 to 0.87 for significant myopia, and the area under the curve was between 0.94 and 0.97. The mean difference between the smartphone-based application and the autorefractor was ≥ +1.00 D (range: +0.13 to +0.38), with a sensitivity of 0.76 and a specificity of 0.97 for significant hypermetropia, and the area under the curve was between 0.88 and 0.96.

CONCLUSION

A smartphone-based application could be used as a screening tool for refractive errors in children, especially in resource-limited settings.

Для цитирования: Syauqie Muhammad, Rif'ati Lutfah, Diarsvitri Wienta, Hastono Sutanto Priyo, Siregar Kemal Nazaruddin, Moeloek Nila Djuwita Farieda. The Fundus Red Reflex Test Using a Smartphone Showed High Accuracy Compared to an Autorefractor to Detect Refractive Errors in Children.. Journal of ophthalmic & vision research. 2026. DOI: 10.18502/jovr.v21.18164.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.