The Peritoneal Dialysis Transfer Set Replacement Procedure.
Аннотация
Peritoneal dialysis transfer sets (extension lines) are replaced every six to nine months to minimize peritoneal dialysis catheter complications. The aim of this study was to compare a revised non-bag transfer set exchange procedure with the standard bag exchange procedure on nursing time, costs, and safety. Thirty-three people were randomized to two groups - a standard bag exchange procedure group (n = 16) and a non-bag transfer set exchange procedure group (n = 17). The standard bag exchange procedure took a median of 32 minutes (interquartile range [IQR] 25 to 38 minutes) compared to the non-bag transfer set exchange procedure of 6 minutes (IQR 4 to 8 minutes) (p Ò 0.0001). There was one episode of peritonitis in each group within the 72-hour follow-up period. The average cost of the non-bag transfer set exchange procedure was $24.54 lower, a 37% cost reduction. This study has shown the revised non-bag transfer set replacement procedure appears to be safe, consume less participant and staff time, and decreases costs.