MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.xcrm.2021.100319

Медицинская библиотека · Cell reports. Medicine · 2021

Intrinsic signal amplification by type III CRISPR-Cas systems provides a sequence-specific SARS-CoV-2 diagnostic.

Santiago-Frangos Andrew, Hall Laina N, Nemudraia Anna, Nemudryi Artem, Krishna Pushya, Wiegand Tanner, Wilkinson Royce A, Snyder Deann T, Hedges Jodi F, Cicha Calvin, Lee Helen H, Graham Ava, Jutila Mark A, Taylor Matthew P, Wiedenheft Blake

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

There is an urgent need for inexpensive new technologies that enable fast, reliable, and scalable detection of viruses. Here, we repurpose the type III CRISPR-Cas system for sensitive and sequence-specific detection of SARS-CoV-2. RNA recognition by the type III CRISPR complex triggers Cas10-mediated polymerase activity, which simultaneously generates pyrophosphates, protons, and cyclic oligonucleotides. We show that all three Cas10-polymerase products are detectable using colorimetric or fluorometric readouts. We design ten guide RNAs that target conserved regions of SARS-CoV-2 genomes. Multiplexing improves the sensitivity of amplification-free RNA detection from 107 copies/μL for a single guide RNA to 106 copies/μL for ten guides. To decrease the limit of detection to levels that are clinically relevant, we developed a two-pot reaction consisting of RT-LAMP followed by T7-transcription and type III CRISPR-based detection. The two-pot reaction has a sensitivity of 200 copies/μL and is completed using patient samples in less than 30 min.

Для цитирования: Santiago-Frangos Andrew, Hall Laina N, Nemudraia Anna, Nemudryi Artem, Krishna Pushya, Wiegand Tanner, Wilkinson Royce A, Snyder Deann T, Hedges Jodi F, Cicha Calvin, Lee Helen H, Graham Ava, Jutila Mark A, Taylor Matthew P, Wiedenheft Blake. Intrinsic signal amplification by type III CRISPR-Cas systems provides a sequence-specific SARS-CoV-2 diagnostic.. Cell reports. Medicine. 2021. DOI: 10.1016/j.xcrm.2021.100319.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.