MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/md.0000000000016757

Медицинская библиотека · Medicine · 2019

Ultrasound-guided percutaneous microwave ablation of parotid gland adenolymphoma: A case report.

Jin Mingyue, Fu Jili, Lu Jianbo, Xu Wanying, Chi Hui, Wang Xue, Cong Zhibin

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

RATIONALE: Parotid gland adenolymphoma is one of the most common benign tumors in parotid gland, and mainly treated by surgery. Despite the widespread of ultrasound-guided percutaneous microwave ablation, there is no report concerning its application in parotid gland adenolymphoma. Herein, we reported a 2-year follow-up result of a male patient underwent ultrasound-guided percutaneous microwave ablation for parotid gland adenolymphoma.

PATIENT CONCERNS: A 73-year-old man was admitted due to a hypoechoic nodule measuring 2.67 × 1.42 × 1.35 cm in posterior-inferior area of parotid gland with a high flow velocity in color Doppler flow imaging.

DIAGNOSE: The lesion was pathologically diagnosed as parotid gland adenolymphoma.

INTERVENTIONS: Ultrasound-guided percutaneous microwave ablation was performed to the tumor due to the fact that the patient refused to receive an open surgery in consideration of older age.

OUTCOMES: The ablation procedure lasted about 2 minutes and 15 seconds, without significant adverse effect. The reduction ratios of tumor at postoperative 1 and 3-month were 53% and 82%, respectively. The tumor was fully absent at postoperative 8-month evaluation. Finally, there was no evident recurrence at postoperative 24-month evaluation.

LESSONS: Ultrasound-guided percutaneous microwave ablation is a safe and effective treatment for parotid gland adenolymphoma, which may serve as a novel alternative approach for patients unsuitable for open surgery.

Для цитирования: Jin Mingyue, Fu Jili, Lu Jianbo, Xu Wanying, Chi Hui, Wang Xue, Cong Zhibin. Ultrasound-guided percutaneous microwave ablation of parotid gland adenolymphoma: A case report.. Medicine. 2019. DOI: 10.1097/md.0000000000016757.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.