Positron Emission Tomography/Magnetic Resonance Imaging (PET/MRI) Versus the Standard of Care Imaging in the Diagnosis of Peritoneal Carcinomatosis.

Furtado Felipe S, Wu Mark Z, Esfahani Shadi A, Ferrone Cristina R, Blaszkowsky Lawrence S, Clark Jeffrey W, Ryan David P, Goyal Lipika, Franses Joseph W, Wo Jennifer Y, Hong Theodore S, Qadan Motaz, Tanabe Kenneth K, Weekes Colin D, Cusack James C, Crafa Francesco, Mahmood Umar, Anderson Mark A, Mojtahed Amirkasra, Hahn Peter F, Caravan Peter, Kilcoyne Aoife, Vangel Mark, Striar Robin M, Rosen Bruce R, Catalano Onofrio A

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To compare positron emission tomography (PET)/magnetic resonance imaging (MRI) to the standard of care imaging (SCI) for the diagnosis of peritoneal carcinomatosis (PC) in primary abdominopelvic malignancies.

SUMMARY BACKGROUND DATA: Identifying PC impacts prognosis and management of multiple cancer types.

METHODS

Adult subjects were prospectively and consecutively enrolled from April 2019 to January 2021. Inclusion criteria were: 1) acquisition of whole-body contrast-enhanced (CE) 18F-fluorodeoxyglucose PET/MRI, 2) pathologically confirmed primary abdominopelvic malignancies. Exclusion criteria were: 1) greater than 4 weeks interval between SCI and PET/MRI, 2) unavailable follow-up. SCI consisted of whole-body CE PET/computed tomography (CT) with diagnostic quality CT, and/or CE-CT of the abdomen and pelvis, and/or CE-MRI of the abdomen±pelvis. If available, pathology or surgical findings served as the reference standard, otherwise, imaging followup was used. When SCI and PET/MRI results disagreed, medical records were checked for management changes. Follow-up data were collected until August 2021.

RESULTS

One hundred sixty-four subjects were included, 85 (52%) were female, and the median age was 60 years (interquartile range 50-69). At a subject level, PET/MRI had higher sensitivity (0.97, 95% CI 0.86-1.00) than SCI (0.54, 95% CI 0.37-0.71), P < 0.001, without a difference in specificity, of 0.95 (95% CI 0.90-0.98) for PET/MRI and 0.98 (95% CI 0.93-1.00) for SCI, P ¼ 0.250. PET/MRI and SCI results disagreed in 19 cases. In 5/19 (26%) of the discordant cases, PET/MRI findings consistent with PC missed on SCI led to management changes.

CONCLUSION

PET/MRI improves detection of PC compared with SCI which frequently changes management.

Для цитирования: Furtado Felipe S, Wu Mark Z, Esfahani Shadi A, Ferrone Cristina R, Blaszkowsky Lawrence S, Clark Jeffrey W, Ryan David P, Goyal Lipika, Franses Joseph W, Wo Jennifer Y, Hong Theodore S, Qadan Motaz, Tanabe Kenneth K, Weekes Colin D, Cusack James C, Crafa Francesco, Mahmood Umar, Anderson Mark A, Mojtahed Amirkasra, Hahn Peter F, Caravan Peter, Kilcoyne Aoife, Vangel Mark, Striar Robin M, Rosen Bruce R, Catalano Onofrio A. Positron Emission Tomography/Magnetic Resonance Imaging (PET/MRI) Versus the Standard of Care Imaging in the Diagnosis of Peritoneal Carcinomatosis.. Annals of surgery. 2022. DOI: 10.1097/sla.0000000000005418.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.