MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-023-39575-8

Медицинская библиотека · Scientific reports · 2023

16S rRNA gene primer choice impacts off-target amplification in human gastrointestinal tract biopsies and microbiome profiling.

Deissová Tereza, Zapletalová Martina, Kunovský Lumír, Kroupa Radek, Grolich Tomáš, Kala Zdeněk, Bořilová Linhartová Petra, Lochman Jan

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

16S rRNA amplicon sequencing or, more recently, metatranscriptomic analysis are currently the only preferred methods for microbial profiling of samples containing a predominant ratio of human to bacterial DNA. However, due to the off-target amplification of human DNA, current protocols are inadequate for bioptic samples. Here we present an efficient, reliable, and affordable method for the bacteriome analysis of clinical samples human DNA content predominates. We determined the microbiota profile in a total of 40 human biopsies of the esophagus, stomach, and duodenum using 16S rRNA amplicon sequencing with the widely used 515F-806R (V4) primers targeting the V4 region, 68F-338R primers and a modified set of 68F-338R (V1-V2M) primers targeting the V1-V2 region. With the V4 primers, on average 70% of amplicon sequence variants (ASV) mapped to the human genome. On the other hand, this off-target amplification was absent when using the V1-V2M primers. Moreover, the V1-V2M primers provided significantly higher taxonomic richness and reproducibility of analysis compared to the V4 primers. We conclude that the V1-V2M 16S rRNA sequencing method is reliable, cost-effective, and applicable for low-bacterial abundant human samples in medical research.

Для цитирования: Deissová Tereza, Zapletalová Martina, Kunovský Lumír, Kroupa Radek, Grolich Tomáš, Kala Zdeněk, Bořilová Linhartová Petra, Lochman Jan. 16S rRNA gene primer choice impacts off-target amplification in human gastrointestinal tract biopsies and microbiome profiling.. Scientific reports. 2023. DOI: 10.1038/s41598-023-39575-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.