Applicability of the Barcelona scale to assess the quality of cleanliness of mucosa at esophagogastroduodenoscopy.
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Córdova Henry, Barreiro-Alonso Eva, Castillo-Regalado Edgar, Cubiella Joaquín, Delgado-Guillena Pedro, Díez Redondo Pilar, Galdín Martin, García-Rodríguez Ana, Hernández Luis, Huerta Alain, Jover Rodrigo, Núñez Henar, Rodríguez-D'Jesús Antonio, Seoane Agustín, Surís Gerard, Tejedor-Tejada Javier, Jiménez Sánchez Javier, Martín Francisco, Moreira Leticia, Carballal Sabela, Rivero Liseth, Da Fieno Angella, Casanova Gherzon, Luzko Scheid Irina, Llach Joan, Fernández-Esparrach Gloria
Аннотация
METHODS: We developed a cleanliness scale (Barcelona scale) with a score (0-2 points) of five segments of the upper gastrointestinal tract with thorough cleaning techniques (esophagus, fundus, body, antrum, and duodenum). First, 125 photos (25 of each area) were assessed, and a score was assigned to each image by consensus among 7 experts endoscopists. Subsequently, 100 of the 125 images were selected and the inter- and intra-observer variability of 15 previously trained endoscopists was evaluated using the same images at two different times.
RESULTS: In total, 1500 assessments were performed. In 1336/1500 observations (89%) there was agreement with the consensus score, with a mean kappa value of 0.83 (0.45-0.96). In the second evaluation, in 1330/1500 observations (89%) there was agreement with the consensus score, with a mean kappa value of 0.82 (0.45-0.93). The intra-observer variability was 0.89 (0.76-0.99).
CONCLUSIONS: The Barcelona cleanliness scale is a valid measure and reproducible with minimal training. Its application in clinical practice is a significant step to standardize the quality of the EGD.