Impact of fully-automated AI based CT-analysis on pre-procedural TAVI planning.

Arsalan Mani, Duske Tami, Schneider Hanna, Tamm Alexander R, Seppelt Philipp Christian, Geyer Martin, Piayda Kerstin, von Bardeleben Ralph Stephan, Martin Simon, Leistner David, Hell Michaela, Walther Thomas, Kreidel Felix

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Accurate pre-procedural computed tomography (CT) analysis is essential for optimal valve sizing and clinical outcomes in transcatheter aortic valve implantation (TAVI). Recently, fully automated, artificial intelligence (AI)-based CT analysis platforms have been developed to simplify and standardize this process.

AIMS: The aim of the study was to investigate the clinical impact of this new analysis method on the selection of valve prosthesis size.

METHODS

Overall, 247 patients with symptomatic severe aortic stenosis were enrolled. Patients underwent TAVI procedures at two different heart centres. The pre-procedural datasets were analysed by a standard TAVI CT-analysis software (3M, Pie Medical Imaging BV, The Netherlands) and a fully-automated CT-analysis-platform employing a deep-learning based algorithm. Key annular measurements and simulated prosthesis size selection were compared between both methods.

RESULTS

The mean aortic annulus diameter was 24.5 ± 2.3 mm (3mensio) and 24.4 ± 2.4 mm (AI), respectively, with a mean absolute error (MAE) of 0.6 mm and mean absolute percentage error (MAPE) of 2.6%. Annulus perimeter (76.9 ± 7.0 mm vs. 74.6 ± 7.3 mm; MAE: 2.0 mm; MAPE: 2.6%) and annulus area (458.4 ± 87.2 mm2 vs. 440.9 ± 85.6 mm2; MAE: 21.2 mm2; MAPE: 4.6%) showed excellent correlation (intraclass correlation coefficients > 0.95). Prosthesis size selection simulated on the basis of AI-derived measurements would have differed from the implanted size in 21% of patients, compared with 14% when using the semi-automated method.

CONCLUSIONS

In this retrospective study, fully automated AI-based CT analysis demonstrated excellent agreement with conventional semi-automated measurements of the aortic annulus. Nevertheless, similar to established planning workflows, expert interpretation remains crucial to integrate the broader anatomical and clinical context required for optimal prosthesis size selection.

Для цитирования: Arsalan Mani, Duske Tami, Schneider Hanna, Tamm Alexander R, Seppelt Philipp Christian, Geyer Martin, Piayda Kerstin, von Bardeleben Ralph Stephan, Martin Simon, Leistner David, Hell Michaela, Walther Thomas, Kreidel Felix. Impact of fully-automated AI based CT-analysis on pre-procedural TAVI planning.. Clinical research in cardiology : official journal of the German Cardiac Society. 2026. DOI: 10.1007/s00392-026-03017-y.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.