MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5056/jnm19025

Медицинская библиотека · Journal of neurogastroenterology and motility · 2019

Elevated Intrabolus Pressure Predicts Abnormal Timed Barium Esophagram in Esophagogastric Junction Outflow Obstruction.

Hoscheit Matthew, Gabbard Scott

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND/AIMS: Timed barium esophagram (TBE) is used the classification of esophageal motility disorders and assessing esophageal function. Currently, there are no published studies examining the relationship between high-resolution manometry and TBE in patients with esophagogastric junction outflow obstruction (EGJOO). This study seeks to evaluate this relationship and identify manometric variables that may indicate further evaluation using TBE.

METHODS

Retrospective review of medical records identified patients with a diagnosis of EGJOO per the Chicago classification version 3.0. TBE was performed using standard protocol. Patients were divided into 2 groups based on complete emptying or persistence of standing barium column at 5 minutes.

RESULTS

Eleven patients were identified with EGJOO who underwent both high-resolution manometry and TBE within 3 months. Five patients had no standing barium column at 5 minutes, while 6 patients had a persistent barium column. Mean age of each group was 54.0 years and 57.8 years, respectively. Patients with abnormal TBE were found to have significantly elevated intrabolus pressure (IBP) compared with patients who had a normal TBE.

CONCLUSIONS

In our study, we found significant differences in IBP between these patient groups. These findings suggest that patients with EGJOO and elevated IBP may prompt further clinical evaluation with TBE in order to clarify clinical diagnosis and guide therapeutic intervention.

Для цитирования: Hoscheit Matthew, Gabbard Scott. Elevated Intrabolus Pressure Predicts Abnormal Timed Barium Esophagram in Esophagogastric Junction Outflow Obstruction.. Journal of neurogastroenterology and motility. 2019. DOI: 10.5056/jnm19025.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.