MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0221812

Медицинская библиотека · PloS one · 2019

A novel lumen-apposing metal stent with an anti-reflux valve for endoscopic ultrasound-guided drainage of pseudocysts and walled-off necrosis: A pilot study.

Cho In Rae, Chung Moon Jae, Jo Jung Hyun, Lee Hee Seung, Park Jeong Youp, Bang Seungmin, Park Seung Woo, Song Si Young

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Pancreatic pseudocysts (PC) and walled-off necrosis (WON) are common complications of severe pancreatitis. Endoscopic ultrasound (EUS)-guided drainage has replaced surgery as the standard treatment for PC/WON. We developed a novel lumen-apposing metal stent (LAMS) with an anti-reflux valve to prevent infectious complications caused by food reflux into the cyst cavity. This retrospective study investigated the efficacy and safety of EUS-guided drainage using this LAMS.

METHODS

We investigated and compared the treatment outcomes and complications rates between EUS-guided drainage using a novel LAMS (n = 10) versus plastic stents (n = 18) from December 2013 to October 2016. Technical success was defined as successful stent placement without immediate complications. Clinical success was defined as resolution of the PC/WON and disappearance of symptoms.

RESULTS

Among 10 patients in LAMS group, 4 patients had complicated PC and 6 patients had WON. In the plastic stent group, 15 and 3 patients had PC and WON, respectively. The median fluid collection size before treatment was 82.5 (interquartile range [IQR], 60.75-118.25) mm and 92.0 (IQR, 75.75-130.25) mm in the LAMS and plastic stent groups, respectively. There were no statistically significant differences in technical success rates (90% vs. 94.4%; p = 0.999), clinical success rates (80% vs. 77.8%; p = 0.999), and complication rates (20% vs. 27.8%; p = 0.999) between the two groups.

CONCLUSIONS

Treatment outcomes of EUS-guided drainage using a novel LAMS were feasible despite the significantly high proportion of WON. The LAMS allowed acceptable treatment outcomes for EUS-guided drainage.

Для цитирования: Cho In Rae, Chung Moon Jae, Jo Jung Hyun, Lee Hee Seung, Park Jeong Youp, Bang Seungmin, Park Seung Woo, Song Si Young. A novel lumen-apposing metal stent with an anti-reflux valve for endoscopic ultrasound-guided drainage of pseudocysts and walled-off necrosis: A pilot study.. PloS one. 2019. DOI: 10.1371/journal.pone.0221812.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.