Clinical impact of different cut-off values in high-resolution manometry systems on diagnosing esophageal motility disorders.

Kuribayashi Shiko, Iwakiri Katsuhiko, Shinozaki Tomohiro, Hosaka Hiroko, Kawada Akiyo, Kawami Noriyuki, Hoshino Shintaro, Takenouchi Nana, Shimoyama Yasuyuki, Kawamura Osamu, Kusano Motoyasu, Uraoka Toshio

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The values of the parameters in the Chicago classification measured by a high-resolution manometry (HRM) system with the Unisensor catheter (Starlet) are significantly different from those measured by the ManoScan. The contraction vigor is categorized by values of the distal contractile integral (DCI) in the Chicago classification v3.0; however, reference values of the DCI in the Starlet and the clinical impact of the different reference values in the Starlet and ManoScan on diagnosing esophageal motility disorders are not known.

METHODS

We evaluated data from a previous report in which ManoScan and Starlet were compared in the same subjects. The DCI values in each system were compared and reference DCI values were calculated. Moreover, diagnoses assessed by Starlet using reference values in ManoScan were compared with those using calculated reference values and those assessed by ManoScan.

RESULTS

There was a significant positive correlation between the DCI values measured by ManoScan and those measured by Starlet (r = 0.80, p < 0.01). Based on a linear functional relationship considering measurement errors, the reference DCI values for diagnosing failed, weak and hypercontractile contraction vigor were calculated as 590.6, 1011.3 and 10,085.8 mmHg-s-cm, respectively, in the Starlet. Therefore, the proposed reference values in the Starlet were 500, 1000 and 10,000 mmHg-s-cm, respectively. When the reference values in the ManoScan were used in the Starlet data, approximately 30% of subjects were diagnosed inappropriately. This issue was resolved using the proposed reference values in the Starlet.

CONCLUSION

Recognizing systemic differences in HRM systems is important.

Для цитирования: Kuribayashi Shiko, Iwakiri Katsuhiko, Shinozaki Tomohiro, Hosaka Hiroko, Kawada Akiyo, Kawami Noriyuki, Hoshino Shintaro, Takenouchi Nana, Shimoyama Yasuyuki, Kawamura Osamu, Kusano Motoyasu, Uraoka Toshio. Clinical impact of different cut-off values in high-resolution manometry systems on diagnosing esophageal motility disorders.. Journal of gastroenterology. 2019. DOI: 10.1007/s00535-019-01608-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.