MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jgh.15780

Медицинская библиотека · Journal of gastroenterology and hepatology · 2022

Value of artificial intelligence with novel tumor tracking technology in the diagnosis of gastric submucosal tumors by contrast-enhanced harmonic endoscopic ultrasonography.

Tanaka Hidekazu, Kamata Ken, Ishihara Rika, Handa Hisashi, Otsuka Yasuo, Yoshida Akihiro, Yoshikawa Tomoe, Ishikawa Rei, Okamoto Ayana, Yamazaki Tomohiro, Nakai Atsushi, Omoto Shunsuke, Minaga Kosuke, Yamao Kentaro, Takenaka Mamoru, Watanabe Tomohiro, Nishida Naoshi, Kudo Masatoshi

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND AIM: Contrast-enhanced harmonic endoscopic ultrasonography (CH-EUS) is useful for the diagnosis of lesions inside and outside the digestive tract. This study evaluated the value of artificial intelligence (AI) in the diagnosis of gastric submucosal tumors by CH-EUS.

METHODS

This retrospective study included 53 patients with gastrointestinal stromal tumors (GISTs) and leiomyomas, all of whom underwent CH-EUS between June 2015 and February 2020. A novel technology, SiamMask, was used to track and trim the lesions in CH-EUS videos. CH-EUS was evaluated by AI using deep learning involving a residual neural network and leave-one-out cross-validation. The diagnostic accuracy of AI in discriminating between GISTs and leiomyomas was assessed and compared with that of blind reading by two expert endosonographers.

RESULTS

Of the 53 patients, 42 had GISTs and 11 had leiomyomas. Mean tumor size was 26.4 mm. The consistency rate of the segment range of the tumor image extracted by SiamMask and marked by the endosonographer was 96% with a Dice coefficient. The sensitivity, specificity, and accuracy of AI in diagnosing GIST were 90.5%, 90.9%, and 90.6%, respectively, whereas those of blind reading were 90.5%, 81.8%, and 88.7%, respectively (P = 0.683). The κ coefficient between the two reviewers was 0.713.

CONCLUSIONS

The diagnostic ability of CH-EUS results evaluated by AI to distinguish between GISTs and leiomyomas was comparable with that of blind reading by expert endosonographers.

Для цитирования: Tanaka Hidekazu, Kamata Ken, Ishihara Rika, Handa Hisashi, Otsuka Yasuo, Yoshida Akihiro, Yoshikawa Tomoe, Ishikawa Rei, Okamoto Ayana, Yamazaki Tomohiro, Nakai Atsushi, Omoto Shunsuke, Minaga Kosuke, Yamao Kentaro, Takenaka Mamoru, Watanabe Tomohiro, Nishida Naoshi, Kudo Masatoshi. Value of artificial intelligence with novel tumor tracking technology in the diagnosis of gastric submucosal tumors by contrast-enhanced harmonic endoscopic ultrasonography.. Journal of gastroenterology and hepatology. 2022. DOI: 10.1111/jgh.15780.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.