DOI 10.1093/sleep/zsag085

Медицинская библиотека · Sleep · 2026

Automatic alveolar ventilation-targeted NIV mode vs polysomnographic titration of fixed pressure in naive patients with chronic respiratory failure.

Matute-Villacís Mónica, Puig Dupre Marta, Gascueña Dunia, Moraleda Anabel, Guerrero Romero Gemma, López-Escuredo Lidia, Dalmases Mireia, Agustí Àlvar, Embid Cristina

СтатьяРандомизированное исследованиеСравнительное исследованиеПеревод в очереди

Аннотация

STUDY

OBJECTIVES

Polysomnographic titration of fixed pressures of non-invasive ventilatory support (NIV) is recommended for patients with chronic hypercapnic respiratory failure (CHRF). Here we compared the effects of NIV titrated manually by PSG vs. fully automatic mode (iVAPS AE) in sleep quality, respiratory events manually scored and estimated by built-in software, nocturnal hypoventilation, daytime arterial blood gases and patient comfort.

METHODS

We studied 26 adult patients (13 female) with CHRF due to COPD (n = 13), neuromuscular disease (n = 8), obesity hypoventilation syndrome (n = 3) and chest wall disorders (n = 2), all naïve to NIV. They were randomized to standard PSG titration of fixed NIV pressures or PSG using "learn target" iVAPS AE mode in two separate nights, both under PSG monitoring.

RESULTS

Main results showed that:(1) there were no significant differences in the reduction of diurnal PaCO2, nocturnal hypoventilation, sleep quality, upper airway obstruction events with both ventilatory modes; (2) the apnea-hypopnea index from built-in software underestimated that manually scored in both ventilatory modes; (3) ventilatory pressures were lower in fixed mode than iVAPS AE mode; (4) patient comfort was higher in fixed mode than iVAPS AE.

CONCLUSIONS

This study shows that iVAPS AE initiated with the "learned target" procedure achieved similar short and long-term ventilatory efficacy to PSG manual bilevel titration. However, its higher pressure levels and lower comfort indicate that the modes are not fully equivalent. Moreover, underestimation of the AHI by the built-in software demands careful interpretation before changing ventilatory settings. Further studies are required to determine the long-term clinical relevance of these differences.

CLINICAL TRIAL INFORMATION: This study was registered at ClinicalTrials.gov under the title "Evaluation of Conventional Non-invasive Mechanical Ventilation (NIV) Versus an Automatic Ventilation Mode". URL: https://clinicaltrials.gov/study/NCT03872167. Registration number: NCT03872167.

Для цитирования: Matute-Villacís Mónica, Puig Dupre Marta, Gascueña Dunia, Moraleda Anabel, Guerrero Romero Gemma, López-Escuredo Lidia, Dalmases Mireia, Agustí Àlvar, Embid Cristina. Automatic alveolar ventilation-targeted NIV mode vs polysomnographic titration of fixed pressure in naive patients with chronic respiratory failure.. Sleep. 2026. DOI: 10.1093/sleep/zsag085.