MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/md.0000000000046970

Медицинская библиотека · Medicine · 2026

Relationship of retinal arteriolar and venular diameters with coronary slow flow phenomenon.

Sahin Kader Eliz, Karatas Mesut, Aydemir Emre, Bilen Abdurrahman, Avci Sedat, Duyuler Serkan, Inanc Ibrahim Halil

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

Coronary slow flow (CSF) is claimed to be a systemic microvascular pathology rather than an isolated cardiac vascular pathology. We aimed to investigate the relation of CSF with retinal vascular calibers. This cross-sectional study enrolled 122 consecutive patients with CSF and 109 age- and sex-matched controls. Central retinal artery equivalent (CRAE), central retinal vein equivalent (CRVE), and artery-vein ratio were measured using Interactive Vessel Analyzer, a semi-automated retinal vascular analyzer. There were significant differences in CRAE, CRVE, and artery-vein ratio between the CSF and control groups (P < .001, .009, and <.001, respectively). Correlation analysis revealed statistically significant negative correlations between CRAE and left anterior descending artery-corrected TIMI frame count, circumflex-TIMI frame count, mean TIMI frame count, systolic blood pressure, diastolic blood pressure, and high-density lipoprotein cholesterol levels (r = -0.373, -0.390, -0.459, -0.416, -0.471, and -0.350, respectively, P < .001 for all), significant positive correlations of CRVE with left anterior descending artery-corrected TIMI frame count, mean TIMI frame count, smoking, and triglyceride levels (r = 0.341, 0.315, 0.404, and 0.447, respectively, P < .001 for all), and significant negative correlations of CRVE with systolic blood pressure and high-density lipoprotein cholesterol levels (r = -0.254 and -0.359, respectively, P < .001 for all). The CSF is closely associated with retinal vascular caliber, suggesting that, it is a systemic generalized microvascular phenomenon. The utility of retinal imaging for CSF screening is worth further investigation.

Для цитирования: Sahin Kader Eliz, Karatas Mesut, Aydemir Emre, Bilen Abdurrahman, Avci Sedat, Duyuler Serkan, Inanc Ibrahim Halil. Relationship of retinal arteriolar and venular diameters with coronary slow flow phenomenon.. Medicine. 2026. DOI: 10.1097/md.0000000000046970.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.