MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ijg.0b013e31820277a9

Медицинская библиотека · Journal of glaucoma · 2012

Effects of static accommodation versus repeated accommodation on intraocular pressure.

Jenssen Frank, Krohn Jørgen

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the influences of static and repeated accommodation on the intraocular pressure (IOP).

MATERIALS AND

METHODS

A randomized, single-blind study was carried out on 33 healthy volunteers aged 20 to 29 years. Baseline IOP was measured after 10 minutes of viewing a distant target. Static accommodation was achieved by letting the volunteers focus for 3 minutes on a near target, which was individually adjusted to induce a 3 D accommodative demand. For the repeated accommodation, the volunteers were instructed to alternately focus on the near and distant target for 3 minutes. The accommodative responses were continuously monitored by an infrared photorefractor (PowerRef II), and Goldmann tonometry was performed immediately after the accommodative procedures.

RESULTS

The IOP values (mean±SD) measured after static and repeated accommodation were 13.4±2.4 mm Hg and 12.7±2.3 mm Hg, respectively (P=0.04). The IOP decreased significantly from baseline after both the static and repeated mode of accommodation with a mean change of -1.76±1.17 mm Hg (range, 0 to 4 mm Hg) and -2.06±1.48 mm Hg (range, 0 to 5 mm Hg), respectively. The IOP drop seemed to be greater after repeated accommodation compared with static accommodation; however, the difference was not statistically significant (P=0.35).

CONCLUSIONS

The IOP was significantly reduced after both static and repeated accommodation. Compared with static accommodation, the repetitive mode of accommodation did not induce a statistically significant additional IOP drop, indicating that aqueous humor outflow is relatively unaffected by frequent ciliary muscle contractions.

Для цитирования: Jenssen Frank, Krohn Jørgen. Effects of static accommodation versus repeated accommodation on intraocular pressure.. Journal of glaucoma. 2012. DOI: 10.1097/ijg.0b013e31820277a9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.