MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081597x-20091016-08

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2009

Ciliary sulcus diameter and two anterior chamber parameters measured by optical coherence tomography and VHF ultrasound.

Piñero David P, Puche Ana Belén Plaza, Alió Jorge L

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the relationship between two anterior chamber anatomical parameters, angle-to-angle and iris pigment end-to-iris pigment end distances, and sulcus-to-sulcus diameter.

METHODS

Twenty eyes without active ocular pathologies or previous ocular surgeries from 20 patients ranging in age from 23 to 51 years were included in this study. Mean spherical equivalent refraction ranged from +5.50 to -7.00 diopters. Angle-to-angle and iris pigment end-to-iris pigment end distances were measured in all cases three times consecutively using two technologies: optical coherence tomography (OCT) and very high-frequency ultrasonography. Sulcus-to-sulcus diameter was additionally obtained by ultrasonography. Correlation, linear regression, intrasession, and interchangeability analysis between parameters was performed.

RESULTS

Mean sulcus-to-sulcus diameter was 11.92+/-0.80 mm. Mean angle-to-angle distance was 12.14+/-0.52 mm for ultrasonography and 12.23+/-0.59 mm for OCT. Mean iris pigment end-to-iris pigment end distance was 12.18+/-0.51 mm for ultrasonography and 12.29+/-0.61 mm for OCT. No statistically significant differences were found among these anatomical parameters (unpaired Student t test, all P>.10). Statistically significant correlations were found between sulcus-to-sulcus diameter and angle-to-angle distance and between sulcus-to-sulcus diameter and iris pigment end-to-iris pigment end distance for both imaging techniques. For ultrasonography, range of agreement was 0.90 mm between sulcus-to-sulcus diameter and angle-to-angle distance and 0.74 mm between sulcus-to-sulcus diameter and iris pigment end-to-iris pigment end distance. These ranges increased to 1.22 mm and 1.14 mm, respectively, for OCT measurements.

CONCLUSIONS

Angle-to-angle and iris pigment end-to-iris pigment end distances are correlated with sulcus-to-sulcus diameter, but they cannot be used as equivalent parameters.

Для цитирования: Piñero David P, Puche Ana Belén Plaza, Alió Jorge L. Ciliary sulcus diameter and two anterior chamber parameters measured by optical coherence tomography and VHF ultrasound.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2009. DOI: 10.3928/1081597x-20091016-08.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.