m+Medelevator.RU
← Поиск публикаций
Clinical radiology · 2011

Diagnostic accuracy of small intestine ultrasonography using an oral contrast agent in Crohn's disease: comparative study from the UK.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Chatu S, Pilcher J, Saxena S K, Fry D H, Pollok R C G

Аннотация

AIM: To evaluate the usefulness of small intestine contrast-enhanced ultrasonography (SICUS) using an oral contrast agent in routine clinical practice by assessing the level of agreement with the established techniques, small bowel follow-through (SBFT) and computed tomography (CT), and diagnostic accuracy compared with the final diagnosis in the detection of small bowel Crohn's disease (CD) and luminal complications in a regional centre.

MATERIALS AND METHODS: All symptomatic known or suspected cases of CD who underwent SICUS were retrospectively reviewed. The level of agreement between SICUS and SBFT, CT, histological findings, and C-reactive protein (CRP) level was assessed using kappa (κ) coefficient. Sensitivity was demonstrated using the final diagnosis as the reference standard defined by the outcome of clinical assessment, follow-up, and results of investigations other than SICUS.

RESULTS: One hundred and forty-three patients underwent SICUS of these 79 (55%) were female. Eighty-six (60%) were known to have CD and 57 (40%) had symptoms suggestive of intestinal disease with no previous diagnosis. Forty-six (55%) of the known CD patients had had at least one previous surgical resection. The sensitivity of SICUS in detecting active small bowel CD in known CD and undiagnosed cases was 93%. The kappa coefficient was 0.88 and 0.91 with SBFT and CT, respectively. SICUS detected nine patients who had one or more small bowel strictures and six patients with a fistula all detected by SBFT or CT.

CONCLUSION: SICUS is not only comparable to SBFT and CT but avoids radiation exposure and should be more widely adopted in the UK as a primary diagnostic procedure and to monitor disease complications in patients with CD.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты