Influence of titanium dioxide and composite on the accuracy of an intraoral scanner for bilateral upper posterior edentulous jaw (Kennedy class I) scanning: An in vitro study.

Vo Hung Manh, Huynh Nam Cong-Nhat, Tran Trang Thi-Ngoc, Hoang Hung Trong, Nguyen Anh Thi-Lan

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

The accuracy of 3-dimensional images produced by the intraoral scanner (IOS) is affected by scanning-aid materials. This in vitro study aimed to elucidate the influence of scanning-aid materials on the accuracy (trueness and precision) of digital scanning on the bilateral upper posterior edentulous jaw (Kennedy class I).

METHODS

The asymmetrical bilateral upper posterior edentulous model (reference model) was generated using a 3D printer with three groups (application of TiO2 powder - composite and no-treatment control). The experimental scans were executed (n = 10 per group) using TRIOS3 (3shape), while one reference scan was obtained by an industrial scanner (Solutionix - C500). Values of trueness and precision were evaluated using the 3D superimposition method on mean deviation values. The accuracy was assessed using mean deviation values following the 3D superimposition method.

RESULTS

IOS had high trueness (20.6 µm), and significant differences were found between the no-treatment and TiO2 groups. Considering the cut-off value of deviations as 300 µm for clinical acceptability, the analysis clarified the most variations in the control group. There was a significant difference between the no-treatment group and others in the maxillary tuberosity area relating to long-span edentulous. The composite group had the best precision values (1.1 µm). Significant differences were found between composite and TiO2 groups (2.7 µm).

CONCLUSIONS

The bilateral upper posterior edentulous jaw digital impressions obtained using IOS were accurate. However, the digital images in the palate and maxillary tuberosity area related to long-span edentulous differed significantly. TiO2-containing powder and composite landmarks affected the accuracy and stability of the IOS.

CLINICAL SIGNIFICANCE: Scanning aid materials can increase the accuracy of the bilateral upper posterior edentulous jaw scanning with IOS.

Для цитирования: Vo Hung Manh, Huynh Nam Cong-Nhat, Tran Trang Thi-Ngoc, Hoang Hung Trong, Nguyen Anh Thi-Lan. Influence of titanium dioxide and composite on the accuracy of an intraoral scanner for bilateral upper posterior edentulous jaw (Kennedy class I) scanning: An in vitro study.. Journal of dentistry. 2023. DOI: 10.1016/j.jdent.2023.104747.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.