MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/cid.13278

Медицинская библиотека · Clinical implant dentistry and related research · 2023

Accuracy of the Yakebot dental implant robotic system versus fully guided static computer-assisted implant surgery template in edentulous jaw implantation: A preliminary clinical study.

Wang Wenxue, Xu Hao, Mei Dongmei, Zhou Chen, Li Xiaojing, Han Ze'yu, Zhou Xiaobin, Li Xin, Zhao Baodong

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: To compare the accuracy of the Yakebot dental implant robotic system with that of fully guided static computer-assisted implant surgery (CAIS) template in edentulous implantation.

MATERIALS AND

METHODS

Thirteen patients with edentulous were recruited and divided into two groups: the Yake robotic system group (experimental) (n = 5) and the CAIS group (control) (n = 8). Postoperative cone-beam computed tomography (CBCT) was performed immediately, and the 3-dimensional positions of implants were obtained and compared with that in the preoperative design. The comparison showed platform, apical, depth, and angular deviations. A value of p < 0.05 was considered statistically significant.

RESULTS

A total of 84 implants (36 in the robotic group and 48 in the CAIS group) were placed. The mean deviation at the implant platform, apex, depth, and angle in the CAIS group was 1.37 ± 0.72 mm, 1.28 ± 0.68 mm, 0.88 ± 0.47 mm, and 3.47 ± 2.02°, respectively. However, the mean deviation at the implant platform, apex, depth, and angle in the robotic group was 0.65 ± 0.25 mm, 0.65 ± 0.22 mm, 0.49 ± 0.24 mm, and 1.43 ± 1.18°, respectively. Significant differences in the four types of deviation (p < 0.05) between the two groups were observed.

CONCLUSION

The accuracy of robotic system in edentulous implant placement was superior to that of the CAIS template, suggesting that robotic system is more accurate, safe, and flexible, can be considered a promising treatment in clinical practice.

Для цитирования: Wang Wenxue, Xu Hao, Mei Dongmei, Zhou Chen, Li Xiaojing, Han Ze'yu, Zhou Xiaobin, Li Xin, Zhao Baodong. Accuracy of the Yakebot dental implant robotic system versus fully guided static computer-assisted implant surgery template in edentulous jaw implantation: A preliminary clinical study.. Clinical implant dentistry and related research. 2023. DOI: 10.1111/cid.13278.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.