DOI 10.1016/j.jdent.2024.104994
Comparison of near-infrared imaging with cone-beam computed tomography for proximal caries detection in permanent dentition: An in vivo study.
Аннотация
OBJECTIVES
This study aimed to evaluate the diagnostic performance of near-infrared imaging (NIRI) and unaided visual examination (UVE) in detecting proximal caries in permanent dentition in comparison with cone-beam computed tomography (CBCT).
METHODS
Patients who underwent NIRI, UVE, and CBCT imaging within 1 week were enrolled. Using CBCT as the reference test, the positive percent agreement (PPA), negative percent agreement (NPA), and overall percent agreement (OPA) of NIRI, UVE, and a combination of the two for detecting proximal caries at different depths and in different tooth locations were assessed. Additionally, the consistency of these diagnostic methods with CBCT was evaluated.
RESULTS
We evaluated 6,084 proximal surfaces and identified 177 CBCT-positive sites. NIRI had a PPA, NPA, and OPA of 68.93 %, 99.09 %, and 98.21 %, respectively, with a substantial agreement with CBCT. When combined with UVE, the PPA increased by approximately 50 % compared with that of UVE alone. Regarding caries at different depths, NIRI outperformed UVE in detecting initial caries (ICDAS 1-2) over moderate-to-advanced caries (ICDAS 3-6). However, the combined use of NIRI and UVE improved the detection of moderate-to-advanced caries. In the anterior teeth region, NIRI exhibited excellent agreement with CBCT, surpassing its performance in the posterior region.
CONCLUSIONS
Although NIRI cannot fully replace radiographic methods, the substantial agreement of NIRI with CBCT in detecting proximal caries highlights its potential as a complementary tool in routine caries screening, especially when combined with UVE.
CLINICAL SIGNIFICANCE: This study highlights the potential of NIRI as a radiation-free method for detecting proximal caries in permanent teeth. Early detection through regular NIRI scanning can lead to timely intervention, improved patient outcomes, and reduced overall disease burden.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.