INTRODUCTION

In vitro fracture resistance of extracted mandibular molars treated with various access cavity designs, including traditional endodontic cavity (TradAC), conservative/contracted endodontic cavity (ConsAC), ninja endodontic cavity (UltraAC), truss endodontic cavity (TrussAC), caries-driven access cavity (CariesAC), and intact teeth, is the focus of this study.

MATERIALS AND

METHODS

Six groups of 20 mandibular molars, totaling 120, were used in the investigation. While the other five groups underwent various access cavity preparations, chemomechanical preparation, and obturation procedures before being repaired with composite resin, Group 1 was left unaltered (the control). A 6 mm round head tip was used to apply the fracture force, which was measured in newtons, at a crosshead speed of 1 mm/min until fracture developed.

RESULTS

According to the current study, the intact control group had the maximum fracture resistance. The access cavity groups' mean values were maximum in CariesAC followed by ConsAC, TrussAC, UltraAC, and TraditonalAC respectively.

CONCLUSION

While among the four minimally invasive designs, CariesAC showed a higher fracture resistance despite the results being statistically insignificant, TradAC had a significantly lower resistance than other conservative access cavity designs.

Для цитирования: Langaliya Akshayraj K, Parmar Girish, Panchal Drashti, Thakkar Jainish, Shah Jinali, Patel Rushvi. Comparative Evaluation of Different Endodontic Access Cavity Designs with Different Burs-An in vitro Experimental Insight into the Aspect of Fracture Resistance.. Journal of pharmacy & bioallied sciences. 2023. DOI: 10.4103/jpbs.jpbs_1038_23.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.