MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1089/end.2021.0706

Медицинская библиотека · Journal of endourology · 2021

Development and Validation of an Objective Scoring Tool for Robot-Assisted Partial Nephrectomy: Scoring for Partial Nephrectomy.

Iqbal Umar, Jing Zhe, Ahmed Youssef, Elsayed Ahmed S, Rogers Craig, Boris Ronald, Porter James, Allaf Mohammad, Badani Ketan, Stifelman Michael, Kaouk Jihad, Terakawa Tomoaki, Hinata Nobuyuki, Aboumohamed Ahmed A, Kauffman Eric, Li Qiang, Abaza Ronney, Guru Khurshid A, Hussein Ahmed A, Eun Daniel

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Objective

To develop a structured and objective scoring tool for assessment of robot-assisted partial nephrectomy (RAPN): Scoring for Partial Nephrectomy (SPaN). Materials and

Methods

Content development: RAPN was deconstructed into 6 domains by a multi-institutional panel of 10 expert robotic surgeons. Performance on each domain was represented on a Likert scale of 1 to 5, with specific descriptions of anchors 1, 3, and 5. Content validation: The Delphi methodology was utilized to achieve consensus about the description of each anchor for each domain in terms of appropriateness of the skill assessed, objectiveness, clarity, and unambiguous wording. The content validity index (CVI) of ≥0.75 was set as cutoff for consensus. Reliability: 15 de-identified videos of RAPN were utilized to determine the inter-rater reliability using linearly weighted percent agreement, and Construct validation of SPaN was described in terms of median scores and odds ratios.

Results

The expert panel reached consensus (CVI ≥0.75) after 2 rounds. Consensus was achieved for 36 (67%) statements in the first round and 18 (33%) after the second round. The final six-domain SPaN included Exposure of the kidney; Identification and dissection of the ureter and gonadal vessels; Dissection of the hilum; Tumor localization and exposure; Clamping and tumor resection; and Renorrhaphy. The linearly weighted percent agreement was >0.75 for all domains. There was no difference between median scores for any domain between attendings and trainees.

Conclusion

Despite the lack of significant construct validity, SPaN is a structured, reliable, and procedure-specific tool that can objectively assesses technical proficiency for RAPN.

Для цитирования: Iqbal Umar, Jing Zhe, Ahmed Youssef, Elsayed Ahmed S, Rogers Craig, Boris Ronald, Porter James, Allaf Mohammad, Badani Ketan, Stifelman Michael, Kaouk Jihad, Terakawa Tomoaki, Hinata Nobuyuki, Aboumohamed Ahmed A, Kauffman Eric, Li Qiang, Abaza Ronney, Guru Khurshid A, Hussein Ahmed A, Eun Daniel. Development and Validation of an Objective Scoring Tool for Robot-Assisted Partial Nephrectomy: Scoring for Partial Nephrectomy.. Journal of endourology. 2021. DOI: 10.1089/end.2021.0706.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.