Медицинская библиотека · Medical physics · 2025

Uncertainty-guided multitask semi-supervised network for the multi-organ segmentation of breast cancer CBCT.

Wang Zi-Yi, Sun Wei, Zhang Heng, Cao Nan-Nan, Ding Jiang-Yi, Sun Jia-Wei, Xie Kai, Gao Liu-Gang, Ni Xin-Ye

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The delineation of organs at risk (OARs) and clinical target volume (CTV) is an important step in adaptive radiotherapy (ART). Cone-beam computed tomography (CBCT) images are easy to obtain in radiotherapy (RT).

OBJECTIVES

This study aims to develop an effective CBCT-guided delineation method for breast cancer ART.

METHODS

A total of 60 planning CT images and 330 CBCT images from 60 patients with breast cancer who underwent breast-conserving surgery were used to develop uncertainty-guided multitask semi-supervised network (UGMNet), which is guided by model segmentation uncertainty and uses intra-task consistency learning to effectively utilize unlabeled data. Branch networks were added to take advantage of the region-level shape constraints and bounding-level distance information of the data. UGMNet was trained with 20% labeled data and a large amount of unlabeled data to obtain the generalized segmentation model (Ours-G). The planning CT image of each patient was then inputted to the generalized model for fine-tuning to establish a personal segmentation model (Ours-P). We compared Ours-G and Ours-P with three classical semi-supervised methods, uncertainty aware mean teacher (UA-MT), dual-task consistency network (DTC), and mutual consistency network (MC-Net+).

RESULTS

Compared with other semi-supervised segmentation model, our proposed method achieved better or equivalent segmentation performance under the same backbone network (3D VNet) and task setting. For CTV delineation, the mean Dice similarity coefficient (DSC) of UA-MT, DTC, MC-Net+, Ours-G, and Ours-P were 0.84, 0.80, 0.60, 0.84, and 0.87, respectively. For the heart, the mean DSC values were 0.82, 0.85, 0.72, 0.86, and 0.89, respectively. For the left lung, the mean DSC values were 0.92, 0.93, 0.91, 0.94, and 0.92, respectively. For the right lung, the mean DSC values were 0.96, 0.94, 0.93, 0.97, and 0.96, respectively. For the spinal cord, the mean DSC values were 0.73, 0.72, 0.77, 0.80, and 0.80, respectively.

CONCLUSIONS

The proposed method realizes effective delineation for CBCT-guided ART using a small amount of labeled data and improves the segmentation accuracy of CTV and OARs on CBCT images using personalized modeling.

Для цитирования: Wang Zi-Yi, Sun Wei, Zhang Heng, Cao Nan-Nan, Ding Jiang-Yi, Sun Jia-Wei, Xie Kai, Gao Liu-Gang, Ni Xin-Ye. Uncertainty-guided multitask semi-supervised network for the multi-organ segmentation of breast cancer CBCT.. Medical physics. 2025. DOI: 10.1002/mp.17728.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.