MedElevator Войти в исследования
← Поиск публикаций

DOI 10.21037/apm-21-598

Медицинская библиотека · Annals of palliative medicine · 2021

Continuous cardiovascular hemodynamics monitoring with pressure recording analytical method in patients under spinal anesthesia for elective cesarean section: a pilot study.

Zhang Xiaoyu, Xu Tao, Jia Lijie, Cao Huimin, Xu Zifeng

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Pressure recording analytical method (PRAM) of MOSTCARE is a minimally invasive system based on mathematical analysis of arterial pressure profile changes and allows continuous recording of hemodynamic measurements. Herein, we aimed to use the MostCare system to investigate the hemodynamics of patients receiving spinal anesthesia during elective cesarean section.

METHODS

In this observational study, we recruited 17 patients scheduled for elective cesarean section. For each patient, we acquired continuous recordings of hemodynamic parameters at 14 key timepoints: surgical admission (two baseline parameters), immediately after the administration of spinal anesthesia, six subsequent time points (2, 4, 6, 8, 10, and 12 min after anesthesia), during peritoneum and uterine incision, during delivery, following the administration of oxytocin, and after surgery had been completed. Statistical analysis was carried out by repeated measures analysis of variance (ANOVA).

RESULTS

During a twelve min period after spinal anesthesia, we observed significant reductions in mean arterial pressure (MAP), dicrotic pressure (Pdic), cardiac index (CI), stroke volume index (SVI), dP/dtmax, and cardiac cycle efficiency (CCE) (P<0.05 for all). However, systemic vascular resistance index (SVRI) was reversely correlated to CI and increased significantly after spinal anesthesia (P<0.05). These hemodynamic parameters return to near basal values after peritoneum incision. Furthermore, there were significant fluctuations in MAP, Pdic and CI after oxytocin administration (P<0.05).

CONCLUSIONS

PRAM of MostCare system revealed significant changes in key hemodynamic parameters undergoing cesarean section with spinal anesthesia. It enables clinicians gain a much better understanding of hemodynamics of parturients and optimize clinical management strategies.

TRIAL REGISTRATION: This study was registered at http://www.chictr.org.cn on 16, July, 2019. No. ChiCTR1900024566.

Для цитирования: Zhang Xiaoyu, Xu Tao, Jia Lijie, Cao Huimin, Xu Zifeng. Continuous cardiovascular hemodynamics monitoring with pressure recording analytical method in patients under spinal anesthesia for elective cesarean section: a pilot study.. Annals of palliative medicine. 2021. DOI: 10.21037/apm-21-598.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.