OBJECTIVES

The blind portal vein puncture remains the most challenging step during transjugular intrahepatic portosystemic shunt (TIPS) creation. We performed a prospective randomised clinical trial to compare three-dimensional (3D) roadmap with CO2 wedged hepatic vein portography for portal vein puncture guidance.

METHODS

Between March 2017 and May 2017, 30 patients were enrolled and randomly allocated to the study group (3D roadmap) or the control group (CO2 wedged hepatic vein portography).

RESULTS

Technical success of TIPS procedures was achieved in all 30 patients. The mean number of needle passes was significantly lower in the study group (2.0 ± 1.0) compared to the control group (3.7 ± 2.5; p = 0.021). A total of six (40%) patients in the study group and three (20%) in the control group required only one puncture for the establishment of TIPS. There were no significant differences in total fluoroscopy time (p = 0.905), total procedure time (p = 0.199) and dose-area product (p = 0.870) between the two groups.

CONCLUSIONS

3D roadmap is a safe and technically feasible means for portal vein puncture guidance during TIPS creation, equivalent in efficacy to CO2 wedged hepatic vein portography. This technique could reduce the number of needle passes, thereby simplifying the TIPS procedure.

KEY POINTS: • 3D roadmap can be used to guide portal vein puncture. • Compared with CO 2 venography, 3D roadmap reduced the number of needle passes. • 3D roadmap has a potential to simplify the TIPS procedure.

Для цитирования: Luo Xuefeng, Wang Xiaoze, Yu Jiaze, Zhu Yongjun, Xi Xiaotan, Ma Huaiyuan, Yang Li. Transjugular intrahepatic portosystemic shunt creation: three-dimensional roadmap versus CO2 wedged hepatic venography.. European radiology. 2018. DOI: 10.1007/s00330-018-5316-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.