MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2460/ajvr.2004.65.544

Медицинская библиотека · American journal of veterinary research · 2004

Three-dimensional motion pattern of the caudal lumbar and lumbosacral portions of the vertebral column of dogs.

Benninger Monika I, Seiler Gabriela S, Robinson Leanne E, Ferguson Stephen J, Bonél Harald M, Busato André R, Lang Johann

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the 3-dimensional motion pattern including main and coupled motions of the caudal lumbar and lumbosacral portions of the vertebral column of dogs.

ANIMALS: Vertebral columns of 9 German Shepherd Dogs (GSDs) and 16 dogs of other breeds with similar body weights and body conditions.

PROCEDURE: Main and coupled motions of the caudal lumbar and lumbosacral portions of the vertebral column (L4 to S1) were determined by use of a testing apparatus that permitted precise application of known pure moments to the vertebral column. Motion was compared between GSDs and dogs of other breeds.

RESULTS

All specimens had a similar motion pattern consisting of main motion and a certain amount of coupled motion including translation. Vertebral columns of GSDs had significantly less main motion in all directions than that of dogs of other breeds. Translation was similar in GSDs and dogs of other breeds and was smallest at the lumbosacral motion segment.

CONCLUSIONS AND CLINICAL RELEVANCE: Results indicated that motion in the caudal lumbar and lumbosacral portions of the vertebral column of dogs is complex and provided a basis for further studies evaluating abnormal vertebral columns.

Для цитирования: Benninger Monika I, Seiler Gabriela S, Robinson Leanne E, Ferguson Stephen J, Bonél Harald M, Busato André R, Lang Johann. Three-dimensional motion pattern of the caudal lumbar and lumbosacral portions of the vertebral column of dogs.. American journal of veterinary research. 2004. DOI: 10.2460/ajvr.2004.65.544.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.