F-18 NaF PET for detection of bone metastases in lung cancer: accuracy, cost-effectiveness, and impact on patient management.

Hetzel Martin, Arslandemir Coskun, König Hans-Helmut, Buck Andreas K, Nüssle Karin, Glatting Gerhard, Gabelmann Andreas, Hetzel Jürgen, Hombach Vinzenz, Schirrmeister Holger

СтатьяПеревод пока не подготовлен

Аннотация

UNLABELLED: As bone metastases might be present in lung cancer despite a normal bone scan, we examined various alternatives prospectively. Positron emission tomography using F-18 sodium fluoride (PET) and single photon emission tomography (SPECT) were more sensitive than a planar bone scan. PET was more accurate with a shorter examination time than SPECT but had higher incremental costs.

INTRODUCTION

Previous studies have shown that vertebral bone metastases not seen on planar bone scans may be present on F-18 fluoride positron emission tomography (PET) scan or single photon emission computed tomography (SPECT). The purpose of this study was to measure the accuracy, clinical value and cost-effectiveness of tomographic bone imaging.

MATERIALS AND

METHODS

A total of 103 patients with initial diagnosis of lung cancer was prospectively examined with planar bone scintigraphy (BS), SPECT of the vertebral column and PET using F-18 sodium fluoride (F-18 PET). Receiver operating characteristic (ROC) curve analysis was used for determination of the diagnostic accuracy. A decision-analysis model and the national charge schedule of the German Hospital Association were used for determination of the cost-effectiveness.

RESULTS

Thirteen of 33 patients with bone metastases were false negative on BS, 4 on SPECT, and 2 on F-18 PET. The area under the ROC curve was 0.771 for BS, 0.875 for SPECT, and 0.989 for F-18 PET (p < 0.05). As a result of SPECT and F-18 PET imaging, clinical management was changed in 8 (7.8%) and 10 (9.7%) patients. Compared with BS, the costs per additional correctly diagnosed patient were 1272 Euro with SPECT and 2861 Euro with F-18 PET. The threshold for the costs of F-18 PET being more cost-effective than SPECT was 345 EUR.

CONCLUSION

Routine performance of tomographic bone imaging improves the therapeutic strategy because of detection of otherwise missed metastases. F-18 PET is more effective than SPECT but is associated with higher incremental costs.

Для цитирования: Hetzel Martin, Arslandemir Coskun, König Hans-Helmut, Buck Andreas K, Nüssle Karin, Glatting Gerhard, Gabelmann Andreas, Hetzel Jürgen, Hombach Vinzenz, Schirrmeister Holger. F-18 NaF PET for detection of bone metastases in lung cancer: accuracy, cost-effectiveness, and impact on patient management.. Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research. 2003. DOI: 10.1359/jbmr.2003.18.12.2206.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.