CT-guided microcoil localization for pulmonary nodules before VATS: a retrospective evaluation of risk factors for pleural marking failure.

Xu Yanyan, Ma Lingchuan, Sun Hongliang, Huang Zhenguo, Zhang Zhenrong, Xiao Fei, Ma Qianli, Li Chuandong, Zhang Xiaomeng, Xie Sheng

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To summarize the experiences of CT-guided microcoil localization before video-assisted thoracoscopic surgery (VATS) and to investigate the risk factors associated with pleural marking failure.

METHODS

Totally, 249 consecutive patients with 279 pulmonary nodules who underwent CT-guided microcoil localization prior to VATS were enrolled in this study. According to intraoperative observation, all the nodules were divided into two groups. The clinical characteristics and microcoil localization procedure-related variables of the nodules were analyzed by univariate analysis and multivariate logistic regression analysis to screen the independent factors associated with procedure results.

RESULTS

Among the 279 nodules, 28 failed to observe the proximal end of the microcoil deployed on visceral pleura during VATS. The logistic regression revealed that needle-pleura angle (≤ 30°: OR = 39.022, p = 0.003), pleura-microcoil distance (≤ 10 mm: OR = 87.054, p < 0.001; 10~20 mm: OR = 10.088, p = 0.010), and presence of pleural indentation (OR = 21.623, p < 0.001) were independent risk factors for pleural marking failure.

CONCLUSIONS

CT-guided microcoil localization for pulmonary nodules is a safe and effective procedure. Small needle-pleura angle (≤ 30°), pleura-microcoil distance (≤ 20 mm), and the presence of pleural indentation during the procedure are significant risk factors contributing to microcoil pleura marking failure.

KEY POINTS: • CT-guided microcoil localization for pulmonary nodules was a safe and effective procedure. • CT-guided microcoil localization for pulmonary nodules yielded low complication rates. • Small needle-pleura angle, short pleura-microcoil distance, and the presence of pleural indentation were contributing to pleura marking failure.

Для цитирования: Xu Yanyan, Ma Lingchuan, Sun Hongliang, Huang Zhenguo, Zhang Zhenrong, Xiao Fei, Ma Qianli, Li Chuandong, Zhang Xiaomeng, Xie Sheng. CT-guided microcoil localization for pulmonary nodules before VATS: a retrospective evaluation of risk factors for pleural marking failure.. European radiology. 2020. DOI: 10.1007/s00330-020-06954-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.