Measurement of innate immune response biomarkers in peritoneal dialysis effluent using a rapid diagnostic point-of-care device as a diagnostic indicator of peritonitis.

Goodlad Catriona, George Sophiamma, Sandoval Shella, Mepham Stephen, Parekh Gita, Eberl Matthias, Topley Nicholas, Davenport Andrew

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Peritonitis is the commonest complication of peritoneal dialysis and a major reason for treatment failure. Current diagnosis is based on clinical symptoms, cloudy effluent and a dialysate white cell count (over 100 cells/μl). A rapid point-of-care diagnostic test would accelerate diagnosis and potentially improve outcomes from infection. Here, in a clinical audit project, we used PERiPLEX®, a point-of-care device which detects when levels of matrix metalloproteinase-8 and interleukin-6 are elevated above a threshold within minutes in dialysis effluent, to assess whether it could confirm or exclude peritonitis in 107 patients undergoing peritoneal dialysis. Mean patient age was 64.6 years with a median duration of peritoneal dialysis of 13.3 months (interquartile range 6.3 - 33.5 months). Presence of peritonitis was confirmed by clinical criteria. There were 49 positive tests of which 41 patients had peritonitis, three had other causes of intra-peritoneal inflammation, three had severe urosepsis and two patients required no treatment. Fifty-eight tests were negative with one patient having a false negative result. The positive predictive value of the test was 83.7% (95% confidence interval 72.8 - 90.8) and the negative predictive value was 98.3% (89.1 - 99.8). Sensitivity and specificity were 97.6% (87.4 - 99.9) and 87.7% (77.2 - 94.5) respectively. Thus, PERiPLEX® could be used as a rapid point-of-care test that can aid the diagnosis or exclusion of peritonitis with a high negative predictive value.

Для цитирования: Goodlad Catriona, George Sophiamma, Sandoval Shella, Mepham Stephen, Parekh Gita, Eberl Matthias, Topley Nicholas, Davenport Andrew. Measurement of innate immune response biomarkers in peritoneal dialysis effluent using a rapid diagnostic point-of-care device as a diagnostic indicator of peritonitis.. Kidney international. 2020. DOI: 10.1016/j.kint.2020.01.044.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.