Polymerase chain reaction/electrospray ionization-mass spectrometry (PCR/ESI-MS) is not suitable for rapid bacterial identification in peritoneal dialysis effluent.

Szeto Cheuk Chun, Ng Jack Kit-Chung, Fung Winston Wing-Shing, Lai Ka-Bik, Chow Kai-Ming, Li Philip Kam-Tao, Massiah Arikana, Alcolea-Medina Adela, Wilks Mark, Fan Stanley L

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Peritoneal dialysis (PD)-related peritonitis is a serious complication of PD, but routine microbiological culture is slow and could not identify the organism in 15% cases. We examine the accuracy of polymerase chain reaction/electrospray ionization-mass spectrometry (PCR/ESI-MS), a PCR-based method developed for the direct detection of bacteria in blood, for rapid identification of microorganisms from PD effluent.

METHODS

We recruited 73 consecutive patients with PD-related peritonitis. Dialysis effluent was collected for routine bacterial culture, PCR/ESI-MS, and bacterial DNA quantification before initiation of antibiotic therapy.

RESULTS

By digital PCR with universal bacterial primers, bacterial DNA was detectable in all PD effluent specimens. For the entire cohort, taking standard bacterial culture as the gold standard, the PCR/ESI-MS assay correctly identified 34.3% of the causative organisms, failed to identify any organism in 52.1% cases, and identified a different organism in 8.2% cases. For the 14 episodes of peritonitis that were culture negative by conventional bacterial culture, the PCR/ESI-MS assay identified an organism in only four cases. The detection rate of the IRIDICA BAC BSI assay was not affected by the use of biocompatible PD solution or concomitant exit-site infection.

CONCLUSIONS

The PCR/ESI-MS assay could not identify the causative organism in over 50% of the PD effluent samples in patients with PD-related peritonitis and should be not used for such purpose. The reason for the poor performance needs further investigation.

Для цитирования: Szeto Cheuk Chun, Ng Jack Kit-Chung, Fung Winston Wing-Shing, Lai Ka-Bik, Chow Kai-Ming, Li Philip Kam-Tao, Massiah Arikana, Alcolea-Medina Adela, Wilks Mark, Fan Stanley L. Polymerase chain reaction/electrospray ionization-mass spectrometry (PCR/ESI-MS) is not suitable for rapid bacterial identification in peritoneal dialysis effluent.. Peritoneal dialysis international : journal of the International Society for Peritoneal Dialysis. 2020. DOI: 10.1177/0896860820917845.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.