BACKGROUND

Percutaneous Endoscopic Gastrostomy (PEG) feeding tubes are frequently placed in patients to provide enteral nutrition. We report a case of a complete rupture of a PEG tube intra-abdominally with associated peritonitis after more than a month of PEG placement and utilization. To our knowledge, this is a very rare case of a complete PEG rupture with the succeeding replacement and recovery of the fractured segments conservatively.

CASE PRESENTATION: A 69-year-old female with a PEG in position and in use for more than a month started complaining of severe abdominal pain. Digital subtraction angiography (DSA) tubogram revealed rupture and separation of the PEG tube into two fragments. Interventional radiology (IR) team was successful with their conservative approach. Both fragments were removed conservatively without the need for laparotomy. The distal fragment was utilized to place a guide wire, and a new PEG was placed in position with no intraabdominal leak.

CONCLUSION

Ruptured PEG tube should be considered in the differential of patients complaining of sudden abdominal pain, especially after chronic PEG utilization. Conservative approach by IR is a viable option in correcting this mishap.

Для цитирования: Al Halabi Maan, Wakim Wakim, Moukaddam Hicham, Husari Ahmad. Conservative recovery and replacement of a ruptured percutaneous endoscopic gastrostomy tube; a case report.. BMC gastroenterology. 2020. DOI: 10.1186/s12876-020-01218-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.