Аннотация

PURPOSE: To determine the bioavailability and pharmacokinetic profile of lumiracoxib from different sites in the gastrointestinal tract.

METHODS

Subjects (11 healthy adult males) were randomized to receive a 100 mg lumiracoxib dose, via a site-specific radiolabeled delivery capsule, to the stomach (internal reference), proximal small bowel, distal small bowel, or ascending colon. Gamma scintigraphy was used for real-time visualization of capsule location, and a radiofrequency signal was used to activate capsules at target site.

RESULTS

Ten subjects completed the study. The mean capsule activation times for the stomach, proximal small bowel, distal small bowel, and ascending colon were 0.22, 1.52, 3.43, and 11.46 h post dose, respectively. Lumiracoxib was well absorbed from the proximal and distal small bowel, with AUC(0-infinity) ratios 104% (86, 127)% and 110% (89, 136)%, respectively. The highest Cmax (2413 ng/ml) and AUC(0-infinity) for lumiracoxib were in the distal small bowel (6842 ng x h/ml). Effective absorption was observed from the ascending colon, with an AUC(0-infinity) ratio of 85% (69, 104)% vs. the reference.

CONCLUSIONS

Lumiracoxib is rapidly and efficiently absorbed throughout the gastrointestinal tract.

Для цитирования: Wilding Ian R, Connor Alyson L, Carpenter Polly, Rordorf Christiane, Branson Janice, Milosavljev Slavica, Scott Graham. Assessment of lumiracoxib bioavailability from targeted sites in the human intestine using remotely activated capsules and gamma scintigraphy.. Pharmaceutical research. 2004. DOI: 10.1023/b:pham.0000019297.07378.bd.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.