Evaluation of bone thickness in the anterior hard palate relative to midsagittal orthodontic implants.

Henriksen Brent, Bavitz Bruce, Kelly Brad, Harn Stanton D

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: The Straumann Orthosystem (Institut Straumann, Waldenburg, Switzerland) describes a technique that involves placement of titanium implants (4 or 6 mm long and 3.3 mm in diameter) into the midsagittal hard palate for orthodontic anchorage. The aim of this study was to determine the quantity of bone in the midline of the anterior hard palate, and specifically the thickness inferior to the incisive canal.

MATERIALS AND

METHODS

Twenty-five dry skulls were radiographed with a standardized cephalometric technique. The vertical thickness of the midsagittal palate was then measured to the nearest tenth of a millimeter. Next, gutta-percha was injected into the incisive canal, and the radiograph was repeated. The bone thicknesses were then measured from the inferior hard palate to the most Inferior part of the radiopaque canal. This is defined as the actual bone available for the implant without violating the canal.

RESULTS

The measurements have shown that an average of 8.6 +/- 1.3 mm of bone is theoretically available for the implant. However, considering the canal (where only bone thickness inferior to it is utilized and measured), only 4.3 +/- 1.6 mm of bone exists. The canal itself averaged 2.5 +/- 0.6 mm in diameter.

DISCUSSION: Prior studies have overestimated the amount of bone available for implants in the median hard palate. The main reason for this is that the incisive canal is not well visualized on cephalometric radiographs of live patients.

CONCLUSION

This study supports the continued use of implants, as approximately 50% of skulls still had the requisite minimum 4 mm of bone inferior to the incisive canal for maximum osseointegration with the 4-mm implants. However, 6-mm implants should be used with caution.

Для цитирования: Henriksen Brent, Bavitz Bruce, Kelly Brad, Harn Stanton D. Evaluation of bone thickness in the anterior hard palate relative to midsagittal orthodontic implants.. The International journal of oral & maxillofacial implants. 2003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.