MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000501057

Медицинская библиотека · Medical principles and practice : international journal of the Kuwait University, Health Science Centre · 2019

Value of Multidetector Computed Tomography in the Assessment of Achalasia Subtypes and Detection of Pulmonary and Thoracic Complications.

Jovanovic Sanja, Djuric-Stefanovic Aleksandra, Simić Aleksandar, Skrobic Ognjan, Pesko Predrag

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate multidetector computed tomography (MDCT) findings in patients with achalasia, to assess its role in differentiating subtypes in detecting lung involvement and extra-esophageal thoracic complications.

SUBJECTS AND

METHODS

This clinical retrospective study included 51 patients with manometrically confirmed achalasia who underwent chest X-ray and MDCT in diagnostic work-up. Esophageal wall thickness and morphology, luminal dilatation, lung changes, and extra-esophageal manifestations were analyzed on MDCT by 2 readers. Wilcoxon, Kruskal-Wallis and Mann-Whitney test were used for assessing the differences among the achalasia subtypes, and intra-class correlation coefficients (ICC) assessing the inter-observer agreement between the measurements of 2 readers.

RESULTS

Fourteen (27.5%) patients had achalasia subtype I, 21 (60.8%) had subtype II while 6 (11.8%) had subtype III. Esophageal wall thickness of the esophageal body (EB) and distal esophageal segment (DES) as well as nodular/lobulated appearance of DES were found significantly more often in subtype III (p = 0.024, p < 0.001, p = 0.009, respectively). Esophageal dilatation gradually decreased from subtype I to III (p = 0.006). Chest X-ray revealed lung changes in 9 (17%) and MDCT in 21 (41%) patients (p = 0.001), most frequently in subtype I, with predominance of ground-glass opacities. Tracheal/carinal compression was detected in 27 (52.9%) and left atrial compression in 17 (33.3%) patients. Excellent inter-observer agreement was observed in measuring the EB and DES wall thickness, and diameter of EB (ICC 0.829, 0.901, and 0.922).

CONCLUSION

MDCT is a useful tool for detecting lung and extra-esophageal thoracic complications in patients with achalasia, and could be a valuable additional imaging modality in the differentiation of achalasia subtypes.

Для цитирования: Jovanovic Sanja, Djuric-Stefanovic Aleksandra, Simić Aleksandar, Skrobic Ognjan, Pesko Predrag. Value of Multidetector Computed Tomography in the Assessment of Achalasia Subtypes and Detection of Pulmonary and Thoracic Complications.. Medical principles and practice : international journal of the Kuwait University, Health Science Centre. 2019. DOI: 10.1159/000501057.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.