Toward optimal organ at risk sparing in complex volumetric modulated arc therapy: an exponential trade-off with target volume dose homogeneity.
Аннотация
PURPOSE: Conventional radiotherapy typically aims for homogenous dose in the planning target volume (PTV) while sparing organs at risk (OAR). The authors quantified and characterized the trade-off between PTV dose inhomogeneity (IH) and OAR sparing in complex head and neck volumetric modulated arc therapy plans.
METHODS
Thirteen simultaneous integrated boost plans were created per patient, for ten patients. PTV boost(B)/elective(E) optimization priorities were systematically increased. IHB and IHE, defined as (100% - V95%) + V107%, were evaluated against the average of the mean dose to the combined composite swallowing and combined salivary organs (D-OAR(comp)). To investigate the influence of OAR size and position with respect to PTVB/E, OAR dose was evaluated against a modified Euclidean distance (DMB/DME) between OAR and PTV.
RESULTS
Although the achievable D-OAR(comp) for a given level of PTV IH differed between patients, excellent logarithmic fits described the D-OAR(comp)/IHB and IHE relationship in all patients (mean R(2) of 0.98 and 0.97, respectively). Allowing an increase in average IHB and IHE over a clinically acceptable range, e.g., from 0.4% ± 0.5% to 2.0% ± 2.0% and 6.9% ± 2.8% to 14.8% ± 2.7%, respectively, corresponded to a decrease in average dose to the composite salivary and swallowing structures from 30.3 ± 6.5 to 23.6 ± 4.7 Gy and 32.5 ± 8.3 to 26.8 ± 9.3 Gy. The increase in PTVE IH was mainly accounted for by an increase in V107, by on average 5.9%, rather than a reduction in V95, which was on average only 2%. A linear correlation was found between the OAR dose to composite swallowing structures and contralateral parotid and submandibular gland, with DME (R(2) = 0.83, 0.88, 0.95). Only mean ipsilateral parotid dose correlated with DMB (R(2) = 0.87).
CONCLUSIONS
OAR sparing is highly dependent on the permitted PTVB/E IH. PTVE IH substantially influences OAR doses. These results are relevant for clinical practice and for future automated treatment-planning strategies.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.