MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2463/mrms.2013-0009

Медицинская библиотека · Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2013

Usefulness of dual echo volumetric isotropic turbo spin echo acquisition (VISTA) in MR imaging of the temporomandibular joint.

Sugimori Yuko, Tanaka Shigeko, Nishimura Tetsuya, Yamamoto Akira, Ohfuji Satoko, Naito Yukari, Katsumata Yasutomo, Miki Yukio

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: We investigated the ability to detect the articular disk and joint effusion of the temporomandibular joint (TMJ) of a method of dual echo volumetric isotropic turbo spin echo acquisition (DE-VISTA) additional fusion images (AFI).

METHODS

DE-VISTA was performed in the 26 TMJ of 13 volunteers and 26 TMJ of 13 patients. Two-dimensional (2D) dual echo turbo spin echo was performed in the 26 TMJ of 13 volunteers. On a workstation, we added proton density-weighted images (PDWI) and T2 weighted images (T2WI) of the DE-VISTA per voxel to reconstruct DE-VISTA-AFI. Two radiologists reviewed these images visually and quantitatively.

RESULTS

Visual evaluation of the articular disk was equivalent between DE-VISTA-AFI and 2D-PDWI. The sliding thin-slab multiplanar reformation (MPR) method of DE-VISTA-AFI could detect all articular disks. The ratio of contrast (CR) of adipose tissue by the articular disk to that of the articular disk itself was significantly higher in DE-VISTA-AFI than DE-VISTA-PDWI (P<0.05) in patients and volunteers with closed or open mouth. In volunteers, the CR between adipose tissue and the disk on DE-VISTA-AFI was marginally significant to that on 2D-PDWI at opened mouth (P=0.071) and not significantly different (P=0.18) from that at closed mouth. Joint effusion could be identified in DE-VISTA-AFI in all 8 joints that had joint effusion in DE-VISTA-T2WI but in only 3 of those joints in 2D-T2WI. The CR of joint effusion to adipose tissue on DE-VISTA-AFI did not differ significantly from that on DE-VISTA-PDWI. However, using DE-VISTA-T2WI in addition to DE-VISTA-PDWI, we could visually identify joint effusion on DE-VISTA-AFI that could not be identified on DE-VISTA-PDWI alone.

CONCLUSION

DE-VISTA-AFI can depict the articular disk and a small amount of joint effusion by the required plane of MPR using the sliding thin-slab MPR method.

Для цитирования: Sugimori Yuko, Tanaka Shigeko, Nishimura Tetsuya, Yamamoto Akira, Ohfuji Satoko, Naito Yukari, Katsumata Yasutomo, Miki Yukio. Usefulness of dual echo volumetric isotropic turbo spin echo acquisition (VISTA) in MR imaging of the temporomandibular joint.. Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine. 2013. DOI: 10.2463/mrms.2013-0009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.