MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3109/00016357.2013.850173

Медицинская библиотека · Acta odontologica Scandinavica · 2013

Effect of water-soluble titanium microparticle-permeated tape on temporomandibular disorders-related pain: a preliminary study.

Nishiyama Akira, Kino Koji, Tsukagoshi Kaori, Tobe Shoko, Otomo Natsuko

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Recent research has focused on the applicability of titanium particle-impregnated materials in healthcare and medical products. This preliminary study was undertaken to investigate the effect of water-soluble titanium microparticle-permeated (WSTi) tape on temporomandibular disorder (TMD)-related pain.

MATERIALS AND

METHODS

The study included 32 patients (41.5 ± 14.4 years, 26 women) who had visited the Temporomandibular Joint Clinic, Tokyo Medical and Dental University, for treatment of TMD-related pain. The subjects were instructed to apply the WSTi tape (AquaTitan tape) on the most painful area before going to sleep and remove the tape on awakening daily for 2 weeks. Seven outcome variables were statistically analyzed: maximum mouth-opening ranges with and without pain, spontaneous pain intensity, mouth-opening pain intensity, chewing pain intensity, TMD-related limitation of daily functions (LDF-TMD) and subjective evaluation of any change in TMD-related pain.

RESULTS

The mean maximum mouth-opening ranges with (p = 0.011) and without (p = 0.002) pain were significantly greater and mean pain intensities on mouth opening (p < 0.001) and chewing (p = 0.001) were significantly lower at the 2-week follow-up than at the baseline. The mean LDF-TMDQ scores were also significantly lower at the 2-week follow-up (p = 0.004). After 2 weeks of using the WSTi tape, 53.1% and 12.5% of the subjects reported a slight improvement and an improvement, respectively, in TMD-related pain.

CONCLUSION

WSTi tape seems to have beneficial effects on TMD-related pain and LDF.

Для цитирования: Nishiyama Akira, Kino Koji, Tsukagoshi Kaori, Tobe Shoko, Otomo Natsuko. Effect of water-soluble titanium microparticle-permeated tape on temporomandibular disorders-related pain: a preliminary study.. Acta odontologica Scandinavica. 2013. DOI: 10.3109/00016357.2013.850173.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.