MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10439-013-0840-4

Медицинская библиотека · Annals of biomedical engineering · 2013

Effect of mechanical strain on solute diffusion in human TMJ discs: an electrical conductivity study.

Wright Gregory J, Kuo Jonathan, Shi Changcheng, Bacro Thierry R H, Slate Elizabeth H, Yao Hai

СтатьяПоддержка NIH: внешняя программаПоддержка правительства СШАПеревод пока не подготовлен

Аннотация

This study investigated the effect of mechanical strain on solute diffusion in human TMJ discs (mean cadaver age 77.8) using the electrical conductivity method. The electrical conductivity, as well as small ion diffusivity, of male and female TMJ discs was determined under three compressive strains. In the male group, the average disc electrical conductivity (mean ± SD) at 0% strain was 5.14 ± 0.97 mS/cm, decreased to 4.50 ± 0.91 mS/cm (-12.3%) at 10% strain, and 3.93 ± 0.81 mS/cm (-23.5%) at 20% compressive strain. Correspondingly, the average disc relative ion diffusivity at 0% strain was 0.44 ± 0.08, decreased to 0.40 ± 0.08 (-8.9%) at 10% strain, and 0.36 ± 0.08 (-16.7%) at 20% compressive strain. In the female group, the average disc electrical conductivity at 0% strain was 5.84 ± 0.59 mS/cm, decreased to 5.01 ± 0.50 mS/cm (-14.2%) at 10% strain, and 4.33 ± 0.46 mS/cm (-25.8%) at 20% compressive strain. Correspondingly, the average disc relative ion diffusivity at 0% strain was 0.49 ± 0.05, decreased to 0.43 ± 0.04 (-11.3%) at 10% strain, and 0.39 ± 0.04 (-19.9%) at 20% compressive strain. The results indicated that mechanical strain significantly impeded solute diffusion through the disc. This mechanical strain effect was larger in the female than in the male human TMJ disc. This study may provide new insights into TMJ pathophysiology.

Для цитирования: Wright Gregory J, Kuo Jonathan, Shi Changcheng, Bacro Thierry R H, Slate Elizabeth H, Yao Hai. Effect of mechanical strain on solute diffusion in human TMJ discs: an electrical conductivity study.. Annals of biomedical engineering. 2013. DOI: 10.1007/s10439-013-0840-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.