MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.gie.2017.01.020

Медицинская библиотека · Gastrointestinal endoscopy · 2017

Providing data for serrated polyp detection rate benchmarks: an analysis of the New Hampshire Colonoscopy Registry.

Anderson Joseph C, Butterly Lynn F, Weiss Julia E, Robinson Christina M

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND AIMS: Similar to achieving adenoma detection rate (ADR) benchmarks to prevent colorectal cancer (CRC), achieving adequate serrated polyp detection rates (SDRs) may be essential to the prevention of CRC associated with the serrated pathway. Previous studies have been based on data from high-volume endoscopists at single academic centers. Based on a hypothesis that ADR is correlated with SDR, we stratified a large, diverse group of endoscopists (n = 77 practicing at 28 centers) into high performers and low performers, based on ADR, to provide data for corresponding target SDR benchmarks.

METHODS

By using colonoscopies in adults aged ≥50 years (4/09-12/14), we stratified endoscopists by high and low ADRs (<15%, 15%-<25%, 25%-<35%, ≥35%) to determine corresponding SDRs by using 2 SDR measures, for screening and surveillance colonoscopies separately: (1) Clinically significant SDR (CSSDR), meaning colonoscopies with any sessile serrated adenoma/polyp (SSA/P), traditional serrated adenoma (TSA), or hyperplastic polyp (HP) >1 cm anywhere in the colon or HP >5 mm in the proximal colon only divided by the total number of screening and surveillance colonoscopies, respectively. (2) Proximal SDR (PSDR) meaning colonoscopies with any serrated polyp (SSA/P, HP, TSA) of any size proximal to the sigmoid colon divided by the total number of screening and surveillance colonoscopies, respectively.

RESULTS

A total of 45,996 (29,960 screening) colonoscopies by 77 endoscopists (28 facilities) were included. Moderately strong positive correlation coefficients were observed for screening ADR/CSSDR (P = .69) and ADR/PSDR (P = .79) and a strong positive correlation (P = .82) for CSSDR/PSDR (P < .0001 for all) was observed. For ADR ≥25%, endoscopists' median (interquartile range) screening CSSDR was 6.8% (4.3%-8.6%) and PSDR was 10.8% (8.6%-16.1%).

CONCLUSIONS

Derived from ADR, the primary colonoscopy quality indicator, our results suggest potential SDR benchmarks (CSSDR = 7% and PSDR = 11%) that may guide adequate serrated polyp detection. Because CSSDR and PSDR are strongly correlated, endoscopists could use the simpler PSDR calculation to assess quality.

Для цитирования: Anderson Joseph C, Butterly Lynn F, Weiss Julia E, Robinson Christina M. Providing data for serrated polyp detection rate benchmarks: an analysis of the New Hampshire Colonoscopy Registry.. Gastrointestinal endoscopy. 2017. DOI: 10.1016/j.gie.2017.01.020.